首页> 外文期刊>Journal of dairy science >Short communication: Validation of a test-day milk test for β-hydroxybutyrate for identifying cows with hyperketonemia
【24h】

Short communication: Validation of a test-day milk test for β-hydroxybutyrate for identifying cows with hyperketonemia

机译:短期通信:验证β-羟基丁酸酯的试日牛奶试验,用于鉴定Hyperketonemia的奶牛

获取原文
获取原文并翻译 | 示例
       

摘要

Subclinical ketosis is a common metabolic disorderaffecting dairy cattle that results in a greater risk forthe development of subsequent metabolic and infectiousdisease. Canwest Dairy Herd Improvement (DHI;Guelph, ON, Canada) has begun to use an infraredtest (MilkoScan FT600, Foss Analytical A/S, Hillerød,Denmark) applied to metered composite milk samplesto detect β-hydroxybutyrate (BHB) levels as a herdsurveillance test for hyperketonemia. However, the testhas not been compared with the gold standard, serumBHB as determined in a reference diagnostic laboratory.The objective of this cross-sectional diagnosticaccuracy study was to validate the DHI milk BHB testto identify cows with hyperketonemia as determined byquantification of BHB in serum. A total of 316 cowsfrom 17 dairy herds in southwestern Ontario had a milkand blood sample taken. Milk was collected at a routineDHI test, and blood from the same cow was sampledwithin 24 h of the milk test. The BHB concentration inmilk was determined using the DHI milk BHB test, andserum was sent to the Animal Health Laboratory at theUniversity of Guelph (Guelph, ON, Canada). A nonparametricreceiver operating characteristic curve wasgenerated to compare DHI milk BHB concentrationswith serum BHB concentrations. Overall, a total of 34cows (11%) had a level of serum BHB ≥1.2 mmol/L.The concentration of DHI milk BHB was moderatelycorrelated with the concentration of serum BHB, yieldinga coefficient of determination value of 0.61. Theoptimal cut point for determining hyperketonemia(≥1.2 mmol/L) on the DHI milk BHB test was ≥0.14mmol/L, yielding a sensitivity of 81% and specificityof 92%. The performance of the DHI milk BHB testvaried depending on the days in milk (DIM) of the cowstested, with a higher specificity being found in cowsthat were ≤25 DIM compared with cows tested >25DIM. If the herd-level prevalence of hyperketonemiawas ≥14%, the DHI milk BHB test had an improvedsensitivity when compared with a herd-level prevalenceof <14%. This study demonstrates that the DHI milkBHB test is a reliable measure for evaluating hyperketonemiausing routine DHI milk samples and could beused as a herd-level monitoring tool for ketosis whenevaluating nutritional management or preventativemedicine strategies.
机译:亚临床刺激是一种常见的代谢紊乱影响奶牛导致更大的风险后续代谢和传染性的发展疾病。 Canwest Dairy牛群改进(DHI;圭尔夫,加拿大)已经开始使用红外线测试(Milkoscan FT600,FOSS Analytical A / S,Hillerød,丹麦)应用于计量复合牛奶样品将β-羟基丁酸酯(BHB)水平检测为牛群高钾血症监测试验。但是,测试尚未与黄金标准进行比较,血清BHB如参考诊断实验室中确定。这种横截面诊断的目的准确性研究是验证DHI牛奶BHB测试鉴定具有高钾血症的奶牛,如确定血清中BHB的定量。共有316奶牛从安大略省西南部的17名乳制牛奶牛奶和血液样本采取。在常规收集牛奶DHI测试和来自同一牛的血液被取样在牛奶试验的24小时内。 BHB浓度使用DHI牛奶BHB测试测定牛奶,和血清被送到动物健康实验室圭尔夫大学(圭尔夫,加拿大)。一个非参场接收器操作特征曲线是产生比较DHI牛奶BHB浓度患有血清BHB浓度。总的来说,共34岁奶牛(11%)具有血清BHB≥1.2mmol/ L水平。DHI牛奶BHB的浓度适度与血清BHB的浓度相关,屈服确定值0.61的系数。这确定高钾血症的最佳切割点(≥1.2mmol/ l)在DHI牛奶BHB测试上≥0.14mmol / L,产生81%和特异性的敏感性92%。 DHI牛奶BHB测试的性能根据奶牛的牛奶(暗淡)的日子而变化测试,在奶牛中发现了更高的特异性与测试的奶牛相比,这是≤25次调光> 25暗淡。如果群血尿血症患病率≥14%,DHI牛奶BHB测试有改进与畜群流行相比的敏感性<14%。这项研究表明DHI牛奶BHB测试是评估高酮血症的可靠度量使用常规DHI牛奶样品,可以用作睾丸级监测工具,用于刺激评估营养管理或预防医学策略。

著录项

  • 来源
    《Journal of dairy science》 |2019年第2期|1589-1593|共5页
  • 作者单位

    Department of Population Medicine University of Guelph Guelph Ontario N1G 2W1 Canada;

    Department of Population Medicine University of Guelph Guelph Ontario N1G 2W1 Canada;

    Department of Population Medicine University of Guelph Guelph Ontario N1G 2W1 Canada;

  • 收录信息 美国《科学引文索引》(SCI);美国《生物学医学文摘》(MEDLINE);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    ketosis; milk; dairy cow;

    机译:酮化酶;牛奶;奶牛;
  • 入库时间 2022-08-18 22:29:34

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号