The paper describes a test programme on columns fabricated from high strength steel plates with nominal yield stress of 690 MPa. The programme comprised 13 box and I-section specimens, including fixed-ended stub columns and pin-ended long columns. For the pin-ended columns, two tests were performed for each length using eccentric and concentric axial loading. The purpose of the test programme was to select a curve for high strength steel columns with a nominal yield stress of 690 MPa from the multiple column curves used in the Australian steel structures standard. It is shown that the α_b = -0.5 curve is the appropriate curve for box and I-section columns fabricated from flame-cut high strength steel plate with a nominal yield stress of 690 MPa. This curve is higher than the α_b = 0 curve for box and I-section columns fabricated from ordinary steel because the effect of residual stresses is less detrimental to the strength of high strength steel columns than to the strength of ordinary steel columns. The paper also shows a comparison of the tests with column design strengths of the Australian steel structures standard AS4100, the load and Resistance Factor Design Specification of the American Institute of Steel Construction, The British Standard BS5950: Part 1, and the draft European Committee for Standardisation (CEN) Eurocode3. The design strengths are shown to be in close agreement with the tests except for Eurocode3 which conservatively predicts the test strengths.
机译:本文描述了由高强度钢板制成的,标称屈服应力为690 MPa的圆柱的测试程序。该程序包括13个箱形和I型截面样本,包括固定端的短柱和销端的长柱。对于销端圆柱,使用偏心和同心轴向载荷对每个长度进行了两次测试。测试程序的目的是从澳大利亚钢结构标准中使用的多列曲线中选择名义屈服应力为690 MPa的高强度钢柱的曲线。结果表明,α_b= -0.5曲线是用标称屈服应力为690 MPa的火焰切割高强度钢板制成的箱形截面和I型截面柱的合适曲线。该曲线高于由普通钢制成的箱形截面和I型截面柱的α_b= 0曲线,因为残余应力的影响对高强度钢柱的强度的损害小于对普通钢柱的强度的不利影响。本文还显示了这些测试与澳大利亚钢结构标准AS4100的立柱设计强度,美国钢结构学会的荷载和抗力系数设计规范,英国标准BS5950:第1部分以及欧洲钢结构标准草案的比较。标准化(CEN)欧洲规范3。事实证明,设计强度与测试非常吻合,但Eurocode3保守地预测了测试强度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号