首页> 外文期刊>Journal of bridge engineering >Increasing Girder Elastic Buckling Strength Using Split Pipe Bearing Stiffeners
【24h】

Increasing Girder Elastic Buckling Strength Using Split Pipe Bearing Stiffeners

机译:使用分体式管道轴承加劲肋提高梁的弹性屈曲强度

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Warping restraining devices can result in substantial improvements in the girder elastic buckling capacity; however, calculating this increase can be complex. This paper presents a simplified method to evaluate the increase in elastic buckling strength and corresponding unbraced length due to improved warping restraint provided by split pipe stiffeners located at the ends of doubly symmetric W-shapes. The solution is based on analytical studies and results from a finite-element parametric study validated using large-scale laboratory tests. The laboratory tests include specimens exposed to concentrated loads with split pipe warp-restraining devices and others with standard plate stiffeners. The proposed analytic method is based on uniform moment and shows that warping restraint can increase the elastic buckling capacity of a girder by 30-100%. The improved warping stiffness can result in increases in the unbraced length in the range of 20-35% compared with systems with plate stiffeners.
机译:翘曲抑制装置可以显着提高梁的弹性屈曲能力;但是,计算此增长可能很复杂。本文提出了一种简化的方法来评估弹性屈曲强度和相应的无支撑长度的增加,这是由于位于双对称W形末端的分叉管加强件提供了改善的翘曲约束而导致的。该解决方案基于分析研究,并使用大型实验室测试验证了有限元参数研究的结果。实验室测试包括使用分流管翘曲抑制装置暴露在集中载荷下的样品,以及使用标准平板加强筋的样品。所提出的分析方法基于均匀力矩,并且表明翘曲约束可以将梁的弹性屈曲能力提高30-100%。与具有板式加劲肋的系统相比,改进的翘曲刚度可导致未支撑长度增加20%至35%。