...
首页> 外文期刊>Journal of biomedical optics >Measurement Of Layer-like Hemodynamic Trends In Scalp And Cortex: Implications For Physiological Baseline Suppression In Functional Near-infrared Spectroscopy
【24h】

Measurement Of Layer-like Hemodynamic Trends In Scalp And Cortex: Implications For Physiological Baseline Suppression In Functional Near-infrared Spectroscopy

机译:头皮和皮质层状血流动力学趋势的测量:对功能性近红外光谱中的生理基线抑制的影响。

获取原文
获取原文并翻译 | 示例
           

摘要

A multidetector, continuous wave, near-infrared spectroscopy (NIRS) system is developed to examine whether the hemody-namics of the scalp and brain in adults contain significant layer-like hemodynamic trends. NIRS measurements are made using contrasting geometries, one with four detectors equidistant from a source 33 mm away, and one with detectors collinear with the source (5 to 33 mm away). When NIRS time series are acquired over the prefrontal cortex from resting adults using both geometries, variations among the time series are consistent with a substantially homogeneous two-layer model (p < 0.001) and inconsistent with one dominated by heterogeneities. Additionally, when time series measured 5 mm from the source are subtracted from corresponding 33-mm signals via a least-squares algorithm, 60% of the hemoglobin changes are on average removed. These results suggest that hemodynamic trends present in the scalp can contribute significantly to NIRS measurements, and that attempts to reduce this noise by subtracting a simultaneous near-channel measurement using a two-layer model are justified. Such subtractions are then performed on NIRS measurements from two stimulus protocols. For systemic stimulations (Valsalva maneuver), the subtraction cancels the hemodynamic response, as desired. For localized stimulation of the occipital lobe (viewing a flickering pattern), the subtraction isolated a stimulus-correlated hemodynamic featurernfrom background noise.
机译:开发了一种多检测器,连续波,近红外光谱(NIRS)系统,以检查成年人头皮和大脑的血流动力学是否包含明显的层状血液动力学趋势。 NIRS测量是使用对比几何结构进行的,其中一种具有四个与距光源33毫米等距的探测器,另一种具有与光源共线(5至33毫米)共线的探测器。当使用这两种几何结构从静止的成年人的前额叶皮层获取NIRS时间序列时,时间序列之间的变化与基本均质的两层模型一致(p <0.001),并且与以异质性为主的模型不一致。此外,当通过最小二乘算法从相应的33毫米信号中减去距光源5毫米处测得的时间序列时,平均可以去除60%的血红蛋白变化。这些结果表明,头皮中存在的血流动力学趋势可能对NIRS测量有显着贡献,并且试图通过减去使用两层模型的同时近通道测量来减少这种噪声是合理的。然后,对来自两个刺激方案的NIRS测量执行此类减法。对于全身性刺激(Valsalva动作),减法可根据需要取消血液动力学反应。为了局部刺激枕叶(观察到闪烁的图案),减法从背景噪声中分离出了与刺激相关的血液动力学特征。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号