Cathode properties of arcs are investigated for ambient gas pressures of 10-3-725 Torr. Copper, silver, and carbon electrodes are used in controlled ambients of either nitrogen, argon, or helium. Experimental techniques include pressure‐dependent observations of the ionized cathode vapor detected at cylindrical collectors surrounding the electrodes, arc photography, and measurements of the cathode erosion rate for copper at 100 A using the weight loss method. At pressures approaching atmospheric, it is shown that the measured erosion rate is reduced from that in vacuum by about an order of magnitude. Increasing the ambient pressure also decreases the distance from the cathode spots at which the 8% ion current can be detected. Data extrapolation shows that cathode spots at atmospheric pressure, particularly in the lighter gases, are still associated with the fundamental ion current. Comparison between the measured reductions in both the erosion rates and the ion currents indicates that vapor and ion redeposition on the cathode contribute to the decreased erosion. It is concluded that the cathode spots of low current arcs at pressures approaching atmospheric are basically similar to vacuum arc cathode spots. The final section of the paper compares current‐dependent erosion data for copper arcs in vacuum and air, and shows the importance of collective cathode spot heating.
机译:研究了环境气压为10-3-725托的电弧的阴极性能。铜,银和碳电极可在氮气,氩气或氦气的受控环境中使用。实验技术包括在电极周围的圆柱形收集器处检测到的离子化阴极蒸气的压力相关观测,电弧照相以及使用失重法测量100 A下铜的阴极腐蚀速率。结果表明,在接近大气压的压力下,测得的腐蚀速率比真空下的腐蚀速率降低了一个数量级。增加环境压力还会减小距阴极点的距离,在阴极点处可以检测到8%的离子电流。数据外推表明,大气压下的阴极斑点,特别是在较轻的气体中,仍与基本离子电流有关。测得的腐蚀速率和离子电流的降低之间的比较表明,阴极上的蒸汽和离子再沉积有助于减少腐蚀。可以得出结论,在接近大气压的压力下,低电流电弧的阴极点基本上类似于真空电弧阴极点。本文的最后一部分比较了真空和空气中铜电弧的电流相关腐蚀数据,并显示了集中阴极点加热的重要性。

著录项

  • 来源
    《Journal of Applied Physics 》 |1974年第12期| P.5235-5244| 共10页
  • 作者

  • 作者单位
  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号