A stagnation temperature probe with a single platinum‐coated silica shield was built for use at high supersonic speeds and elevated temperatures. For large Reynolds numbers the temperature recovery factor of the probe reaches 0.998. It decreases with decreasing Reynolds number and increasing temperature. At temperatures up to 700° K the major thermometric losses of the probe are conduction losses. One single calibration curve is obtained for any one probe by relating the calibration data to the flow conditions inside the probe.
机译:带有单铂涂层二氧化硅防护罩的停滞温度探头专为在超音速和高温下使用而设计。对于较大的雷诺数,探头的温度恢复系数达到0.998。它随着雷诺数的减少和温度的升高而降低。在高达700°K的温度下,探头的主要测温损耗是传导损耗。通过将校准数据与探头内部的流动条件相关联,可以为任何一根探头获得一条单一的校准曲线。

著录项

  • 来源
    《Journal of Applied Physics 》 |1954年第2期| 共2页
  • 作者

    Winkler Eva M.;

  • 作者单位

    U. S. Naval Ordnance Laboratory, White Oak, Silver Spring, Maryland;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);