首页> 外文期刊>Journal of Analytical Atomic Spectrometry >More than ten percent ionization efficiency for Tc measurement by negative thermal ionization mass spectrometry
【24h】

More than ten percent ionization efficiency for Tc measurement by negative thermal ionization mass spectrometry

机译:负热电离质谱用于Tc测量的电离效率超过百分之十

获取原文
获取原文并翻译 | 示例
           

摘要

The accurate determination of ultra-trace amounts of Tc-99 is still a challenge due to its long half-life and the lack of a commercially available isotopic tracer. Negative thermal ionization mass spectrometry (N-TIMS) has been proven to be a powerful method for the analysis of isotopes with relatively high ionization potentials. In this work, we established a novel method based on N-TIMS for the measurement of Tc isotopes. By using Pt filaments and Ba(OH)(2) as the ionization activator, the ionization efficiency of Tc was significantly improved to be more than 10%. The oxygen isotopic compositions were measured with a Tc-99 standard solution and the obtained coefficients can be applied directly for the correction of interferences from oxygen isotopes. We used this method for the measurement of the isotopic abundance and concentration of the Tc-97 tracer produced in our laboratory. Due to the high ionization efficiency of this method and the calibration of the Tc-97 tracer, ultra-trace determination of Tc-99 in radioactive wastes and environmental samples is now possible.
机译:由于Tc-99的半衰期长且缺乏市售的同位素示踪剂,因此准确测定超痕量的Tc-99仍然是一个挑战。负热电离质谱(N-TIMS)已被证明是用于分析具有相对高电离势的同位素的强大方法。在这项工作中,我们建立了一种基于N-TIMS的Tc同位素测量新方法。通过使用Pt灯丝和Ba(OH)(2)作为电离活化剂,Tc的电离效率显着提高到10%以上。用Tc-99标准溶液测量氧同位素组成,所得系数可直接用于校正氧同位素的干扰。我们使用这种方法测量了我们实验室生产的Tc-97示踪剂的同位素丰度和浓度。由于该方法的高电离效率和Tc-97示踪剂的校准,现在可以对放射性废物和环境样品中的Tc-99进行超痕量测定。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号