首页> 外文期刊>Journal of Analytical Atomic Spectrometry >Speciation of gadolinium based MRI contrast agents in environmental water samples using hydrophilic interaction chromatography hyphenated with inductively coupled plasma mass spectrometry
【24h】

Speciation of gadolinium based MRI contrast agents in environmental water samples using hydrophilic interaction chromatography hyphenated with inductively coupled plasma mass spectrometry

机译:电感耦合等离子体质谱联用亲水相互作用色谱法测定环境水样品中of基MRI造影剂

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

A highly sensitive method for the determination of gadolinium based MRI contrast agents in environmental water samples has been developed using hydrophilic interaction chromatography (HILIC) coupled with inductively coupled plasma mass spectrometry (ICP-MS). The contrast agents used in the present study are Gd-DTPA (Magnevist), Gd-DTPA-BMA (Omniscan), Gd-DOTA (Dotarem), Gd-BOPTA (Multihance) and Gd-BT-DO3A (Gadovist) which represent both classes of linear and macro cyclic and also ionic and non ionic contrast agents. A study of various parameters responsible for the efficient separation was performed and resulted in an optimum mobile phase composition of 20 mmol L~(-1) ammonium acetate in 60/40 CAN/water mixture at a flow rate of 0.1 mL min~(-1) in combination with a micro concentric type PFA nebuliser and ICP-MS detection of the ~(158)Gd isotope. All contrast agents have shown excellent linearity between 0.1 μg L~(-1) and 100 μg L~(-1) (R~2 > 0.99) for each MRI contrast agent with RSD values found to be less than 2% for triplicate measurements. The limit of quantification (LOQ) for all contrast agents were found to be less than 100 ng L~(-1) which allows the developed method to be employed in environmental trace analysis. Enrichment of water samples for the determination of contrast agents was performed by using a surface evaporation approach. The developed method has been applied successfully for the separation and determination of contrast agents in surface and waste water treatment plant samples. The MRI agent speciation results were compared with ICP-MS measurements for the total Gd concentrations.
机译:使用亲水相互作用色谱法(HILIC)和电感耦合等离子体质谱法(ICP-MS),开发了一种测定环境水样品中of基MRI造影剂的高灵敏度方法。本研究中使用的造影剂是Gd-DTPA(Magnevist),Gd-DTPA-BMA(Omniscan),Gd-DOTA(Dotarem),Gd-BOPTA(Multihance)和Gd-BT-DO3A(Gadovist)一类的线性和大环型以及离子型和非离子型造影剂。进行了负责有效分离的各种参数的研究,得出了在60/40 CAN /水混合物中流速为0.1 mL min〜(-)的最佳流动相组成为20 mmol L〜(-1)醋酸铵。 1)结合微同心型PFA雾化器和ICP-MS检测〜(158)Gd同位素。对于每种MRI造影剂,所有造影剂均显示出0.1μgL〜(-1)和100μgL〜(-1)之间的出色线性(R〜2> 0.99),三次重复测量的RSD值小于2% 。发现所有造影剂的定量限(LOQ)均小于100 ng L〜(-1),这使得所开发的方法可用于环境痕量分析。通过使用表面蒸发法富集水样以确定造影剂。所开发的方法已成功应用于地表水和废水处理厂样品中造影剂的分离和测定。将MRI试剂的形态结果与ICP-MS测量的总Gd浓度进行了比较。

著录项

  • 来源
    《Journal of Analytical Atomic Spectrometry》 |2010年第1期|55-61|共7页
  • 作者单位

    BAM Federal Institute for Materials Research and Testing, Richard-Willstaetter-Str. 11, 12489 Berlin, Germany;

    BAM Federal Institute for Materials Research and Testing, Richard-Willstaetter-Str. 11, 12489 Berlin, Germany;

    BAM Federal Institute for Materials Research and Testing, Richard-Willstaetter-Str. 11, 12489 Berlin, Germany;

    BAM Federal Institute for Materials Research and Testing, Richard-Willstaetter-Str. 11, 12489 Berlin, Germany Humboldt-Universitael zu Berlin, Department of Chemistry, Brook- Taylor-Strasse 2, 12489 Berlin, Germany;