首页> 外文期刊>Journal of Analytical Atomic Spectrometry >Ultrasound-assisted hollow fiber/ionic liquid-based liquid phase microextraction using an ionic liquid solvent for preconcentration of cobalt and nickel ions in urine samples prior to FAAS determination
【24h】

Ultrasound-assisted hollow fiber/ionic liquid-based liquid phase microextraction using an ionic liquid solvent for preconcentration of cobalt and nickel ions in urine samples prior to FAAS determination

机译:超声辅助中空纤维/离子液体基液相微萃取,使用离子液体溶剂在FAAS测定之前对尿液样品中的钴和镍离子进行预浓缩

获取原文
获取原文并翻译 | 示例
           

摘要

Ultrasound-assisted (UA) hollow fiber (HF) liquid-phase microextraction (LPME) coupled with flame atomic absorption spectrometry (FAAS) has been developed to preconcentrate and determine ultra-trace amounts of cobalt (Co) and nickel (Ni) ions in human urine. To the best of our knowledge, no previous reports have described the coupling of UA-ionic liquid (IL)-HF-LPME with an FAAS system to analyze metal ions in biological samples. In this study, the ILs 1-hexyl-3-methylimidazolium hexafluorophosphate, sodium hexafluorophosphate, and l-(2-pyridylazo)-2-naphthol were used as extraction, ion-pairing, and chelating agents, respectively. With the assistance of an ultrasonic probe, the analyte exchange between the phases increased, and the extraction efficiency of Co and Ni ions improved significantly. The collected extraction phase was subsequently analyzed directly through FAAS. Under optimized conditions, the detection limits of Co and Ni ions were 0.09 and 0.03 μg L~(-1), respectively. The precision of the analysis of Co and Ni ions was within a relative standard deviation of 10% under normal operating conditions. The ultrasonic assistance provided enrichment factors of 66 and 82 for Co and Ni ions, respectively. The recoveries of Co and Ni ions spiked in urine samples ranged from 93.8 to 104.3%. The practicality of the proposed method was demonstrated through satisfactory analyses of samples of a standard reference material and real human urine.
机译:超声辅助(UA)中空纤维(HF)液相微萃取(LPME)结合火焰原子吸收光谱法(FAAS)可以预富集并测定其中的痕量钴(Co)和镍(Ni)离子的超痕量人尿。据我们所知,以前没有报告描述过UA离子液体(IL)-HF-LPME与FAAS系统的耦合以分析生物样品中的金属离子。在这项研究中,ILs 1-己基-3-甲基咪唑六氟磷酸盐,六氟磷酸钠和1-(2-吡啶基偶氮)-2-萘酚分别用作提取剂,离子对和螯合剂。借助超声探头,两相之间的分析物交换增加,Co和Ni离子的萃取效率显着提高。随后通过FAAS直接分析收集的萃取相。在最佳条件下,Co和Ni离子的检出限分别为0.09和0.03μgL〜(-1)。在正常工作条件下,Co和Ni离子的分析精度在10%的相对标准偏差内。超声波辅助分别为Co和Ni离子提供了66和82的富集因子。尿样中加标的Co和Ni离子的回收率为93.8%至104.3%。通过对标准参考物质和真实人类尿液样品的满意分析,证明了该方法的实用性。

著录项

  • 来源
    《Journal of Analytical Atomic Spectrometry》 |2016年第11期|2338-2345|共8页
  • 作者单位

    Department of Medical Laboratory Science and Biotechnology, Kaohsiung Medical University, No. 100, Shih-Chuan 1st Road, Kaohsiung 807, Taiwan;

    Department of Medical Laboratory Science and Biotechnology, Kaohsiung Medical University, No. 100, Shih-Chuan 1st Road, Kaohsiung 807, Taiwan;

    Department of Public Health, Kaohsiung Medical University, Kaohsiung, Taiwan;

    Research Center for Environmental Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan;

    Department of Medical Laboratory Science and Biotechnology, Kaohsiung Medical University, No. 100, Shih-Chuan 1st Road, Kaohsiung 807, Taiwan,Department of Laboratory Medicine, Kaohsiung Medical University Hospital, Kaohsiung, Taiwan;

    Department of Medical Laboratory Science and Biotechnology, Kaohsiung Medical University, No. 100, Shih-Chuan 1st Road, Kaohsiung 807, Taiwan,Department of Laboratory Medicine, Kaohsiung Medical University Hospital, Kaohsiung, Taiwan;

    Department of Medical Laboratory Science and Biotechnology, Kaohsiung Medical University, No. 100, Shih-Chuan 1st Road, Kaohsiung 807, Taiwan,Department of Laboratory Medicine, Kaohsiung Medical University Hospital, Kaohsiung, Taiwan,Department of Chemistry, National Sun Yat-sen University, Kaohsiung, Taiwan;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号