首页> 外文期刊>Journal of Analytical Atomic Spectrometry >Rare earth element determination in heavy crude oil by USN-ICP-MS after digestion using a microwave-assisted single reaction chamber
【24h】

Rare earth element determination in heavy crude oil by USN-ICP-MS after digestion using a microwave-assisted single reaction chamber

机译:微波辅助单反应室消解后,通过USN-ICP-MS测定重质原油中的稀土元素

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

In this work a method for rare earth element (REE) determination by inductively coupled plasma mass spectrometry (ICP-MS) with an ultrasonic nebulizer (USN) was proposed after heavy crude oil digestion by microwave-assisted wet digestion (MAWD) using a single reaction chamber (SRC) system. Operational conditions of the MAWD-SRC method, such as sample mass (from 250 to 1000 mg), type and volume of digestion solutions, temperature achieved during digestion (from 200 to 270 ℃) and microwave irradiation time (35, 40, 45 and 50 min) were investigated. Using optimized digestion conditions, the carbon concentration and residual acidity in digests were 2345 mg L~(-1) and 14.6%, respectively. Since the acidity was low and dilution was not required after digestion by the MAWD-SRC method, lower limits of quantification (LOQs) were obtained (0.1 up to 2 ng g~(-1)) and the determination of some analytes present in very low concentration was possible. It was possible to digest a relatively high crude oil mass (up to 1 g) using 8 mL of 14.4 mol L~(-1) HNO_3 in just 40 min, which can be considered as an important aspect taking into account the difficulties involved in heavy crude oil digestion for further REE determination by ICP-MS. The accuracy was evaluated by analyte spike and also by comparison of results obtained by MAWD-SRC with those using conventional MAWD and also by microwave-induced combustion. Suitable recoveries were obtained for all analytes (94 to 110%) and no statistical difference was observed between the results obtained by MAWD-SRC and those using other methods.
机译:在这项工作中,提出了一种在微波辅助湿法消化(MAWD)的情况下,使用单次超声通过电感耦合等离子体质谱法(ICP-MS)和超声波雾化器(USN)测定稀土元素(REE)的方法。反应室(SRC)系统。 MAWD-SRC方法的操作条件,例如样品质量(250至1000 mg),消解溶液的类型和体积,消解过程中达到的温度(200至270℃)以及微波照射时间(35、40、45和50分钟)进行了调查。在优化的消化条件下,消化液中的碳浓度和残留酸度分别为2345 mg L〜(-1)和14.6%。由于酸度低且通过MAWD-SRC方法消解后无需稀释,因此获得了较低的定量限(LOQs)(0.1至2 ng g〜(-1)),并测定了低浓度是可能的。仅用40分钟,就可以使用8 mL的14.4 mol L〜(-1)HNO_3消化相对较高的原油质量(最高1 g),这被认为是重要的一个方面重质原油消化,以便通过ICP-MS进一步确定REE。通过分析物加标以及通过将MAWD-SRC与使用常规MAWD以及通过微波诱导的燃烧所获得的结果进行比较来评估准确性。对于所有分析物(94%至110%)均获得了合适的回收率,并且MAWD-SRC与使用其他方法得到的结果之间没有统计学差异。

著录项

  • 来源
    《Journal of Analytical Atomic Spectrometry》 |2016年第6期|1185-1191|共7页
  • 作者单位

    Departamento de Quimica, Universidade Federal de Santa Maria, 97105-900, Santa Maria, RS, Brazil;

    Departamento de Quimica, Universidade Federal de Santa Maria, 97105-900, Santa Maria, RS, Brazil;

    Departamento de Quimica, Universidade Federal de Santa Maria, 97105-900, Santa Maria, RS, Brazil;

    Centro de Ciencias Quimicas, Farmaceuticas e de Alimentos, Universidade Federal de Pelotas, 96010-610, Pelotas, RS, Brazil;

    Departamento de Quimica, Universidade Federal de Santa Maria, 97105-900, Santa Maria, RS, Brazil;

    Departamento de Quimica, Universidade Federal de Santa Maria, 97105-900, Santa Maria, RS, Brazil;