首页> 外文期刊>International Orthopaedics >Is MIPO in humeral shaft fractures really safe? Postoperative ultrasonographic evaluation
【24h】

Is MIPO in humeral shaft fractures really safe? Postoperative ultrasonographic evaluation

机译:MIPO在肱骨干骨折中真的安全吗?术后超声检查评估

获取原文
获取原文并翻译 | 示例
       

摘要

In the last few years there has been great interest in minimally invasive plate osteosynthesis (MIPO) in the treatment of humeral shaft fractures. None of these studies showed the anatomical relationship between the radial nerve and the material of the implant in vivo. We performed postoperative ultrasonographic measurement of the distance between the radial nerve and the material implanted using the MIPO technique. Nineteen patients underwent postoperative ultrasound examinations. Group A comprised midshaft fractures and group B distal third fractures. The point of greatest proximity between the radial nerve and the implant was measured. In group A the distance was between 1.6 and 19.6 mm (mean: 9.3 mm) and in group B between 1.0 and 8.1 mm (mean: 4.0 mm). The ultrasound findings reveal that the radial nerve is quite close to the implant material, especially in the transition between the third and fourth quarters of the humeral shaft.
机译:在过去的几年中,在治疗肱骨干骨折中,微创钢板固定术(MIPO)引起了人们极大的兴趣。这些研究均未显示showed神经与体内植入物材料之间的解剖关系。我们对M神经和使用MIPO技术植入的材料之间的距离进行了术后超声检查。十九名患者接受了术后超声检查。 A组包括中轴骨折和B组远端第三骨折。测量了nerve神经和植入物之间的最大接近点。在A组中,该距离在1.6至19.6mm之间(平均:9.3mm),在B组中,该距离在1.0至8.1mm之间(平均:4.0mm)。超声结果显示the神经非常靠近植入物,特别是在肱骨干的第三和第四季度之间的过渡期。