Air mixer design for residential indoor air conditioning unit tests is explored with the assistance of computational fluid dynamics for a closed loop indoor unit test configuration. This test setup does not require a dedicated psychrometric test room, and air coming out of an indoor unit is circulated in a closed loop. The key design requirement for this approach is achieving desired uniform temperature distribution in returning air. The mixing performance of a conventional louver baffle and a cyclone type mixers is compared in this study. It is found that mixing performance can be varied as temperature measurement grids and the measurement may not represent the actual bulk air temperature. Although the considered louver baffle type has better mixing capability than the cyclone type in simulated conditions, an improved mixer design with a carefully arranged sensor grid is still needed to meet the industry standard and represent bulk air status.
机译:在闭环室内机测试配置的计算流体动力学的帮助下,探索了用于住宅室内空调机测试的空气混合器设计。此测试设置不需要专用的湿度测试室,并且从室内机出来的空气在闭环中循环。这种方法的关键设计要求是在回风中实现所需的均匀温度分布。在这项研究中,比较了传统百叶窗挡板和旋风混合器的混合性能。已经发现,随着温度测量网格的变化,混合性能可能会发生变化,并且该测量可能无法代表实际的总体空气温度。尽管在模拟条件下考虑的百叶窗挡板类型具有比旋风分离器类型更好的混合能力,但仍需要改进的混合器设计以及精心布置的传感器网格,以满足行业标准并代表大风量状态。