Structural behavior of an assembled steel joint composed of CHS KK-joint and a doubler plate for connection with steel tensile rods was studied. A full-scale test was conducted for the assembled joint on a special made self-balanced reaction frame with three high strength steel strands to apply tensile loads on two ear plates and compressive load on the chord member of the joint. Ultimate load carrying capacity, failure mode and stress distribution of the joint under monotonic loads were obtained experimentally. The static behavior of the joint was also determined by nonlinear finite element analysis. The results of numerical analysis agreed very well with those of the test, which verified the rationality of the finite element model. The hysteretic behavior of the joint was then studied by finite element analysis. Hysteretic curve was obtained, based on which ductile ratio and energy dissipation factor were calculated. Outcomes from both the test and the finite element analysis proved that the assembled joint has satisfactory load carrying capacity and acceptable seismic performance.
机译:研究了由CHS KK接头和用于连接钢拉力杆的双层板组成的组装钢接头的结构性能。在特制的自平衡反力框架上对组装的关节进行了全面测试,该框架具有三根高强度钢绞线,以在两个耳板上施加拉伸载荷,并在关节的弦杆上施加压缩载荷。通过实验获得了单调载荷作用下节点的极限承载力,破坏模式和应力分布。接头的静态行为也通过非线性有限元分析确定。数值分析结果与试验结果吻合得很好,验证了有限元模型的合理性。然后通过有限元分析研究了接头的滞后行为。得到了磁滞曲线,并据此计算出延性比和能量耗散系数。试验和有限元分析的结果都表明,组装好的接头具有令人满意的承载能力和可接受的抗震性能。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号