首页> 外文期刊>International journal of steel structures >End Plate-Stiffener Connection for SHS Column and RHS Beam in Steel-Framed Building Modules
【24h】

End Plate-Stiffener Connection for SHS Column and RHS Beam in Steel-Framed Building Modules

机译:钢框架建筑模块中的SHS柱和RHS梁的端板加强件连接

获取原文
获取原文并翻译 | 示例
           

摘要

This paper investigates the mechanical performance of beam-to-column connections for steel-framed building modules with RHS and SHS sections of relatively small member sizes. In the experimental program, three forms of connections are tested under static bending, including a completely welded connection (W), a bolted end plate connection (EP) and the proposed end plate-stiffener connection (ST), and the failure modes, moment-rotation behaviours and strain responses were recorded during experiments. Results show that ST connection exhibited superior connection strength, stiffness and ductility compared with the EP connection. In addition, a detailed finite element analysis was conducted to model the connection behaviours, considering bolt pretension, contact behaviours and detailed bolt geometry, showing good comparison with experiments. Furthermore, a parametric study was performed on the end plate thickness and stiffener thickness for the proposed end plate-stiffener connection. Such results finally enable a comparative study to investigate the performance of module during road transportation, highlighting the effects of connection stiffness.
机译:本文研究了钢框架与rhs和Shs段的钢框架建筑模块的机械性能,具有相对小的成员尺寸。在实验程序中,在静态弯曲下测试三种形式的连接,包括完全焊接连接(W),螺栓端板连接(EP)和所提出的端板 - 加强件连接(ST),以及失效模式 - 在实验期间记录了行为和应变响应。结果表明,与EP连接相比,ST连接表现出卓越的连接强度,刚度和延展性。此外,考虑到螺栓预拉,接触行为和详细的螺栓几何形状,进行详细的有限元分析以模拟连接行为,显示出与实验的良好比较。此外,对所提出的端板 - 加强件连接的端板厚度和加强件厚度进行参数研究。这些结果最终使比较研究能够研究道路运输过程中模块的性能,突出了连接刚度的影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号