首页> 外文期刊>International journal of steel structures >Failure Analysis of Fatigue Cracking in the Tension Clamp of a Rail Fastening System
【24h】

Failure Analysis of Fatigue Cracking in the Tension Clamp of a Rail Fastening System

机译:轨道紧固系统张紧夹疲劳裂纹失效分析。

获取原文
获取原文并翻译 | 示例
           

摘要

Fatigue cracking was recently discovered in the tension clamp (SKL15) of a rail fastening system during its service life. Here, the fatigue strengths of SKL15 and SKLB15 (used for replacement) tension clamps were assessed using field measurements and finite element analyses. The strain and displacement of these tension clamps were measured both in a laboratory and at the section of railway track where the original fatigue cracking occurred. Due to limited access to the exact crack initiation location, the strain gauge was instead installed nearby. Finite element analysis was conducted to obtain the stress conditions at the crack initiation location. Extremely high stresses were produced after the installation of tension clamps SKL15 and SKLB15, and this allowed small stress amplitudes for fatigue cracking. The fatigue strengths of the clamps were evaluated using Goodman and Gerber curves. The stress amplitude of the SKL15 was greater than the allowable stress amplitude, presenting the possibility of fatigue cracking.
机译:最近,在钢轨紧固系统的张紧夹(SKL15)的使用寿命中发现了疲劳裂纹。在这里,使用现场测量和有限元分析评估了SKL15和SKLB15(用于替换)张力夹的疲劳强度。这些张力夹的应变和位移是在实验室和原始疲劳裂纹发生的铁路轨道部分进行测量的。由于无法准确到达裂纹的起始位置,因此将应变仪安装在附近。进行了有限元分析以获得裂纹起始位置的应力条件。在安装了张力夹SKL15和SKLB15后产生了极高的应力,这使得疲劳裂纹的应力幅值较小。使用Goodman和Gerber曲线评估夹具的疲劳强度。 SKL15的应力幅值大于允许的应力幅值,存在疲劳裂纹的可能性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信