首页> 外文期刊>International Journal for Ion Mobility Spectrometry >Corona discharge ion mobility spectrometry for the determination of theophylline and guaifenesin in human serum
【24h】

Corona discharge ion mobility spectrometry for the determination of theophylline and guaifenesin in human serum

机译:电晕放电离子淌度光谱法测定人血清中的茶碱和愈创甘油醚

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

This paper describes the determination of theophylline and guaifenesin in human serum using ion mobility spectrometry with positive corona discharge as source ionization. The optimization of parameters that could influence ion mobility spectrometry was investigated. Under optimum conditions (Temperature; injection: 220 and oven: 175 °C, Flow rate; carrier: 300 and drift: 600 mL min−1, Voltage; corona: 2300 and drift: 7000 V, pulse width: 100 μs), calibration curves were linear in the ranges of 2 to120 and 6 to 120 ng for theophylline and guaifenesin, respectively. The relative standard deviation (n = 10) was below 12 %. The detection limits were found to be 0.1 ng for theophylline and 0.5 ng for guaifenesin. The recovery results for the theophylline and guaifenesin determination in human serum was about 80 % that indicate the proposed method can be applied for the two drugs analysis in real sample. Furthermore, the proposed method has been evaluated in the simultaneous determination of the two drugs.
机译:本文介绍了使用正电晕放电作为离子源电离的离子迁移谱法测定人血清中的茶碱和愈创甘油醚。研究了可能影响离子迁移谱的参数的优化。在最佳条件下(温度;进样量:220和烤箱:175°C,流速;载体:300和漂移:600mLmin-1,电压;电晕:2300和漂移:7000V,脉冲宽度:100μs),校准茶碱和愈创甘油醚的曲线分别在2至120和6至120 ng范围内呈线性关系。相对标准偏差(n = 10)低于12%。茶碱的检出限为0.1ng,愈创甘油醚的检出限为0.5ng。人血清中茶碱和愈创甘油醚的回收率约为80%,表明该方法可用于实际样品中两种药物的分析。此外,在同时测定两种药物中对提出的方法进行了评估。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号