The strain rate sensitivity of polyurea is characterized using a modified split Hopkinson pressure bar (SHPB) system. The device is composed of a hydraulic piston along with nylon input and output bars. In combination with an advanced wave deconvolution method, the modified SHPB system provides an unlimited measurement time and thus can be used to perform experiments at low, intermediate and high strain rates. A series of compression tests of polyurea is performed using the modified SHPB system. In addition, conventional SHPB systems as well as a universal hydraulic testing machine are employed to confirm the validity of the modified SHBP technique at low and high strain rates. The analysis of the data at intermediate strain rates shows that the strain rate is not constant due to multiple wave reflections within the input and output bars. It is demonstrated that intermediate strain rate SHPB experiments require either very long bars (>20 m) or very short bars (<0.5 m) in order to achieve an approximately constant strain rate throughout the entire experiment.
机译:聚脲的应变速率敏感性使用改进的霍普金森分压式压力棒(SHPB)系统进行了表征。该设备由液压活塞以及尼龙输入和输出杆组成。结合先进的波解卷积方法,改进的SHPB系统可提供无限的测量时间,因此可用于在低,中和高应变率下进行实验。使用改良的SHPB系统进行一系列的聚脲压缩试验。另外,常规的SHPB系统以及通用液压试验机被用来确认改进的SHBP技术在低应变率和高应变率下的有效性。对处于中间应变率的数据进行的分析表明,由于输入和输出条中的多次波反射,应变率不是恒定的。结果表明,中等应变速率SHPB实验需要非常长的钢筋(> 20 m)或非常短的钢筋(<0.5 m),才能在整个实验中获得大致恒定的应变速率。

著录项

  • 来源
    《International journal of impact engineering》 |2009年第9期|1116-1127|共12页
  • 作者

    Jongmin Shim; Dirk Mohr;

  • 作者单位

    Impact and Crashworthiness Laboratory, Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA;

    Impact and Crashworthiness Laboratory, Department of Mechanical Engineering, Massachusetts Institute of Technology. Room 5-222. 77 Massachusetts Avenue, Cambridge, MA 02139, USA Solid Mechanics Laboratory (CNRS-UMR 7649), Department of Mechanics, Ecole Polytechnique, Palaiseau, France;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    split Hopkinson pressure bar; wave deconvolution; polyurea; intermediate strain rates;

    机译:分开的霍普金森压力杆;波反卷积聚脲中等应变率;
  • 入库时间 2022-08-17 13:04:48

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号