This paper mainly presents the AC impedance characteristics of a 2 kW PEMFC stack under different operating conditions and load changes. The AC impedances of the fuel cell stack are examined by a fuel cell impedance meter. Air stoichiometry, air humidity, and operation temperature are shown to have significant effects on the AC impedance of stack. When air stoichiometry decreases, the mass transfer resistance of stack increases obviously, but the influences on other resistances are very slight. The air humidity and operation temperature mainly influence the charge transfer resistance of stack. The influences of load changes on the AC impedance of stack are also investigated, and the results of which show that it is quite necessary to adjust the humidity of reactant gas according to the fuel cell load changes during fuel cell running. The AC impedance diagnosis of stack can provide some useful information for the running of fuel cell stack.
机译:本文主要介绍2 kW PEMFC电池组在不同工作条件和负载变化下的交流阻抗特性。通过燃料电池阻抗计检查燃料电池堆的AC阻抗。空气化学计量,空气湿度和工作温度对烟囱的交流阻抗有重要影响。当空气化学计量比降低时,烟囱的传质阻力明显增加,但对其他阻力的影响很小。空气湿度和工作温度主要影响电池堆的电荷转移电阻。还研究了负载变化对电池组交流阻抗的影响,其结果表明,在燃料电池运行过程中,有必要根据燃料电池负载变化来调节反应气体的湿度。堆的交流阻抗诊断可以为燃料电池堆的运行提供一些有用的信息。