首页> 外文期刊>International journal of hydrogen energy >Identification of failed cells inside PEMFC stacks in two cases: Anode/cathode crossover and anode/cooling compartment leak
【24h】

Identification of failed cells inside PEMFC stacks in two cases: Anode/cathode crossover and anode/cooling compartment leak

机译:在两种情况下识别PEMFC堆内部的失效电池:阳极/阴极交叉和阳极/冷却室泄漏

获取原文
获取原文并翻译 | 示例
       

摘要

Various PEMFC operating conditions can lead to irreversible damages as membrane break and gasket deterioration. If leak check procedures can highlight the lack of tightness in fuel cells, they are not appropriate to inform actually where the fault has occurred in the stacks. Thus, diagnosis procedures allowing the failed cells to be identified are needed. Then, these cells can be removed and replaced by safe ones. The article presents some descriptions of aged assemblies subjected to anode/cathode crossover and anode/cooling compartment leakage. Some experimental investigations are carried out with the goal to locate the defective cells. The open current voltages of the cells are monitored and analysed in different operating conditions. Experimental procedures combined with data analysis tools allow the detection of the failed cells, which show abnormal performance and voltage pattern when they are compared to the other safe cells.
机译:各种PEMFC操作条件会导致不可逆的损坏,如膜破裂和垫圈变质。如果泄漏检查程序可以突出显示燃料电池缺乏密封性,则不适合实际告知电池堆故障的位置。因此,需要允许识别出故障细胞的诊断程序。然后,可以将这些电池卸下并用安全的电池更换。本文介绍了对经受阳极/阴极交叉和阳极/冷却室泄漏的老化组件的一些描述。为了定位缺陷电池,进行了一些实验研究。在不同的工作条件下对电池的开路电压进行监控和分析。实验程序与数据分析工具相结合,可以检测出失效的电池,当与其他安全电池进行比较时,它们会显示出异常的性能和电压模式。

著录项

  • 来源
    《International journal of hydrogen energy》 |2010年第7期|2772-2776|共5页
  • 作者单位

    Tsinghua University, State Key Laboratory of Automotive Safety and Energy Department of Automotive Engineering, Tsinghua University, Beijing 100084, PR China;

    rnFEMTO-ST (UMR CNRS 6174), ENISYS Department, University of Franche-Comte, France FC LAB, rue Thierry Mieg, 90010 BELFORT Cedex, France;

    rnFC LAB, rue Thierry Mieg, 90010 BELFORT Cedex, France INRETS, The French National Institute for Transport and Safety Research, France;

    rnFC LAB, rue Thierry Mieg, 90010 BELFORT Cedex, France INRETS, The French National Institute for Transport and Safety Research, France;

    rnFEMTO-ST (UMR CNRS 6174), ENISYS Department, University of Franche-Comte, France FC LAB, rue Thierry Mieg, 90010 BELFORT Cedex, France;

    rnFC LAB, rue Thierry Mieg, 90010 BELFORT Cedex, France University of Technology Belfort Montbeliard, France;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    PEM fuel cell; reliability; diagnosis; leakage;