首页> 外文期刊>International journal of hydrogen energy >Comparative study of the break in process of post doped and sol-gel high temperature proton exchange membrane fuel cells
【24h】

Comparative study of the break in process of post doped and sol-gel high temperature proton exchange membrane fuel cells

机译:后掺杂和溶胶-凝胶高温质子交换膜燃料电池断裂过程的比较研究

获取原文
获取原文并翻译 | 示例
       

摘要

In this paper six High Temperature PEM (HTPEM) MEAs from two manufacturers have been tested. The MEAs are three Dapozol 77 from Danish Power Systems (DPS) with varying electrode composition and two Celtec P2100 and one Celtec P1000 from BASF. The break in process of the MEAs has been monitored using voltage measurements and impedance spectroscopy. The purpose of this study is twofold. One aim is to try and interpret the processes happening during break in. The other aim is to investigate whether the impedance spectra or the voltage profiles contain information that can be used to determine when an MEA has been broken in. To aid in the interpretation of the impedance spectra, equivalent circuit models are used. Three models are evaluated. The most detailed models produce the best fits but the most simple model is chosen, since it produces the most consistent results. The processes happening during break in cannot be determined with certainty but for the Celtec P MEAs the main changes seem to be related to improved electrode kinetics. Judging from the voltage and the fitted resistances, the Celtec P MEAs seem to have been broken in after 30 h. The Dapozol MEAs only undergo minor changes in impedance and voltage during the break in period. This may indicate that this MEA type can be used directly without the need for break in.
机译:在本文中,已经测试了两个制造商的六个高温PEM(HTPEM)MEA。 MEA是来自丹麦动力系统公司(DPS)的三台Dapozol 77,电极组成各不相同,以及巴斯夫的两台Celtec P2100和一台Celtec P1000。 MEA的过程中断已使用电压测量和阻抗谱进行了监控。这项研究的目的是双重的。一个目的是尝试解释插入过程中发生的过程。另一个目的是研究阻抗谱或电压曲线是否包含可用于确定MEA何时被侵入的信息。阻抗谱,使用等效电路模型。评估了三个模型。最详细的模型会产生最佳拟合,但会选择最简单的模型,因为它会产生最一致的结果。无法确定磨合过程中发生的过程,但对于Celtec P MEA而言,主要变化似乎与改善的电极动力学有关。从电压和适合的电阻来看,Celtec P MEA在30小时后似乎已损坏。在中断期间,达波唑MEA的阻抗和电压仅发生微小变化。这可能表明该MEA类型无需中断即可直接使用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号