首页> 外文期刊>International Journal of Exergy >Energetic and exergetic analysis of a multi-stage turbine, coal-fired 173 MW power plant
【24h】

Energetic and exergetic analysis of a multi-stage turbine, coal-fired 173 MW power plant

机译:多级涡轮173 MW燃煤电厂的能量和能量分析

获取原文
获取原文并翻译 | 示例

摘要

This paper reports the results of an energy and exergy audit of a 173 MW pulverised coal fired, subcritical steam power plant unit in the Midwestern USA. Energy and exergy analysis determined the thermal efficiency and identified the greatest sources of irreversibilities and also mapped the flow of energy and exergy throughout the plant. The overall plant energetic and exergetic efficiencies were found to be 32.8% and 33.7%, respectively. The largest source of exergy destruction in the cycle was found to be within the steam generator. Options explored to increase the exergetic efficiency were to improve the steam turbines to operate with higher temperature steam, to bring water into the condenser from the lake that is closer to the ambient temperature, and to replace a valve after the boiler feedwater pump with a hydro-turbine to produce some power.
机译:本文报告了美国中西部一个173兆瓦的粉煤燃烧亚临界蒸汽发电厂的能源和火用审计结果。能源和火用分析确定了热效率并确定了不可逆性的最大根源,并绘制了整个工厂的能源和火用流图。发现植物的整体能量效率和能量效率分别为32.8%和33.7%。发现循环中最大的火用破坏源是在蒸汽发生器内。为提高能源利用效率而探索的选择方案包括:改善蒸汽轮机以使其在较高温度的蒸汽下运行;将水从更接近环境温度的湖中引入冷凝器;以及在锅炉给水泵后用水力发电装置更换阀门-涡轮机产生动力。