...
首页> 外文期刊>International journal of environmental analytical chemistry >The graphene oxide/magnesium-aluminium bimetallic hydroxides composite used as solid-phase extractant for determination of monoaromatic hydrocarbons in wastewater
【24h】

The graphene oxide/magnesium-aluminium bimetallic hydroxides composite used as solid-phase extractant for determination of monoaromatic hydrocarbons in wastewater

机译:石墨烯/镁 - 铝双金属氢氧化物复合物用作固相取出剂,用于测定废水中单芳烃烃

获取原文
获取原文并翻译 | 示例
           

摘要

The graphene oxide (GO) and the magnesium-aluminium bimetallic hydroxides composite (GO/Mg-Al-LDH) was used as a solid-phase extractant for determination of toluene, ethylbenzene, p-xylene, m-xylene, o-xylene, 1,3,5-trimethylbenzene and 1,2,4-trimethylbenzene in wastewater by gas chromatography-mass spectrometry analytical method. When the amount of solid-phase extractant was 1.5 g, the extraction time was 6 min, and the elution with 2 mL of chloroform for 3 min, seven monoaromatic hydrocarbons (MAHCs) in 500 mL of water sample can be well extracted and separated. Under the optimised experimental conditions, the mass concentration of each component in the range of 0.01-5 ng/mL has a good linear relationship with the peak area, the coefficients of determination are all greater than 0.995. The relative standard deviation (n = 5) and the method detection limit range are 2.9-7.1% and 0.0005-0.005 ng/mL, respectively. The seven of MAHCs in Dongfengqu River and laboratory wastewater of Chengdu University of Technology can be effectively detected, the recovery rate and the relative standard deviation (n = 5) are 83.0-110.0% and 3.7-9.4%, respectively. For the first time, the GO/Mg-Al-LDH composite was used as a solid-phase extraction material, and seven MAHCs in water were successfully determined by GC-MS. The detection method is established with low detection limit and high reproducibility which can meet the measurement requirements of trace MAHCs in wastewater.
机译:将石墨烯(GO)和镁 - 铝双金属氢氧化物复合物(GO / Mg-Al-LDH)用作固相取出剂,用于测定甲苯,乙苯,对二甲苯,M-甲烷,O-二甲苯,通过气相色谱 - 质谱分析方法将1,3,5-三甲基苯和1,2,4-三甲基苯并下废水。当固相萃取剂的量为1.5g时,提取时间为6分钟,用2ml氯仿3分钟的洗脱,500ml水样中的七种单芳族烃(MAHC)可以很好地提取并分离。在优化的实验条件下,0.01-5ng / ml范围内的每个组分的质量浓度具有与峰面积的良好线性关系,测定系数大于0.995。相对标准偏差(n = 5)和方法检测极限范围分别为2.9-7.1%和0.0005-0.005ng / ml。东风曲河七十多家MAHCS和成都工业大学的实验室废水分别有效地检测,分别恢复率和相对标准偏差(N = 5)分别为83.0-110.0%和3.7-9.4%。首次使用Go / Mg-Al-LDH复合材料作为固相萃取材料,通过GC-MS成功地确定水中的7个MAHC。通过低检测极限和高再现性建立检测方法,其能够满足废水中痕量MAHCS的测量要求。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号