首页> 外文期刊>International journal of environmental analytical chemistry >The graphene oxide/magnesium-aluminium bimetallic hydroxides composite used as solid-phase extractant for determination of monoaromatic hydrocarbons in wastewater
【24h】

The graphene oxide/magnesium-aluminium bimetallic hydroxides composite used as solid-phase extractant for determination of monoaromatic hydrocarbons in wastewater

机译:氧化石墨烯/镁铝双金属氢氧化物复合物用作固相萃取剂测定废水中的单芳烃

获取原文
获取原文并翻译 | 示例
           

摘要

The graphene oxide (GO) and the magnesium-aluminium bimetallic hydroxides composite (GO/Mg-Al-LDH) was used as a solid-phase extractant for determination of toluene, ethylbenzene, p-xylene, m-xylene, o-xylene, 1,3,5-trimethylbenzene and 1,2,4-trimethylbenzene in wastewater by gas chromatography-mass spectrometry analytical method. When the amount of solid-phase extractant was 1.5 g, the extraction time was 6 min, and the elution with 2 mL of chloroform for 3 min, seven monoaromatic hydrocarbons (MAHCs) in 500 mL of water sample can be well extracted and separated. Under the optimised experimental conditions, the mass concentration of each component in the range of 0.01-5 ng/mL has a good linear relationship with the peak area, the coefficients of determination are all greater than 0.995. The relative standard deviation (n = 5) and the method detection limit range are 2.9-7.1% and 0.0005-0.005 ng/mL, respectively. The seven of MAHCs in Dongfengqu River and laboratory wastewater of Chengdu University of Technology can be effectively detected, the recovery rate and the relative standard deviation (n = 5) are 83.0-110.0% and 3.7-9.4%, respectively. For the first time, the GO/Mg-Al-LDH composite was used as a solid-phase extraction material, and seven MAHCs in water were successfully determined by GC-MS. The detection method is established with low detection limit and high reproducibility which can meet the measurement requirements of trace MAHCs in wastewater.
机译:氧化石墨烯(GO)和镁铝双金属氢氧化物复合物(GO / Mg-Al-LDH)被用作固相萃取剂,用于测定甲苯,乙苯,对二甲苯,间二甲苯,邻二甲苯,气相色谱-质谱法分析废水中的1,3,5-三甲苯和1,2,4-三甲苯当固相萃取剂的量为1.5 g时,萃取时间为6分钟,用2 mL氯仿洗脱3 min,可以很好地萃取和分离500 mL水样品中的七种单芳烃(MAHC)。在优化的实验条件下,各组分的质量浓度在0.01-5 ng / mL范围内与峰面积具有良好的线性关系,测定系数均大于0.995。相对标准偏差(n = 5)和方法检测极限范围分别为2.9-7.1%和0.0005-0.005 ng / mL。可以有效地检测出东风渠河中的7种MAHC和成都理工大学的实验室废水,其回收率和相对标准偏差(n = 5)分别为83.0-110.0%和3.7-9.4%。首次将GO / Mg-Al-LDH复合材料用作固相萃取材料,并通过GC-MS成功测定了水中的7种MAHC。建立了检测限低,重现性高的检测方法,可以满足废水中痕量MAHCs的检测要求。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号