首页> 外文期刊>International journal of environmental analytical chemistry >Development of chromatographic methods by using direct-sampling procedure for the quantification of cyclic and linear volatile methylsiloxanes in biogas as perspective for application in online systems
【24h】

Development of chromatographic methods by using direct-sampling procedure for the quantification of cyclic and linear volatile methylsiloxanes in biogas as perspective for application in online systems

机译:通过使用直接进样程序对沼气中的环状和线性挥发性甲基硅氧烷进行定量的色谱方法的开发作为在线系统中应用的前景

获取原文
获取原文并翻译 | 示例
       

摘要

By empirically examining the persistent theme, we hope to produce a more complete understanding of methods for determination of volatile methylsiloxanes in biogas stream. Therefore, we made an attempt to investigate a rapid and sensitive method for simultaneous analysis of linear and cyclic volatile methylsiloxanes in sewage biogas in the context of the perspective for application in online systems. The gas chromatographic (GC) parameters were optimised, and sampling of volatile methylsiloxanes from biogas was performed using novel direct sampling procedure with applying of three kinds of liquid-media. Through application of well-established gas chromatography technique coupled with two types of detector - flamed ionisation detector and mass spectrometer detector - we developed the characterisation of the presented methods. Moreover, during the samples preparation the extraction procedure was consistently excluded, as well as the time of analysis was significantly reduced. The analyses were carried out by applying special constructed sampling train where the absorbed VMSs were trapped and analysed directly by GC technique, afterwards. The instrumental analytical protocol was found to yield a linear calibration in the range 0.1-55.13 (μg g~(-1)) with R~2 values 0.996 and in the range from 0.1 to 65.17 μg g~(-1)) with R~2 values > 0.99 for GC-FID and GC-MS method respectively. In all analysed samples linear and cyclic VMSs were found in sewage gas with quantities exceeding 4.6 mg Nm~(-3) and 19.9 mg Nm~(-3), respectively Furthermore, estimation of VMSs solvent absorption efficiency was tested and the highest absorption efficiency was obtained when acetone was used as a primary solvent. High range of linearity (0.1-65.17 μg/g), and low values of limit of detection (0.01 μg/g), limit of quantification (0.04 μg/g) clearly indicate that the analysis can be successfully repeated in other independent laboratory. The proposed method creates the real perspective for analyis of VMSs in on-line system.
机译:通过实证研究持久性主题,我们希望对测定沼气中挥发性甲基硅氧烷的方法有一个更完整的了解。因此,我们尝试在在线系统中应用的背景下研究一种快速灵敏的方法,用于同时分析污水沼气中的线性和环状挥发性甲基硅氧烷。优化了气相色谱(GC)参数,并使用三种液体介质,采用新颖的直接进样程序对沼气中的挥发性甲基硅氧烷进行了采样。通过将成熟的气相色谱技术与两种类型的检测器(火焰电离检测器和质谱检测器)结合使用,我们开发了所提出方法的表征。此外,在样品制备过程中,提取程序始终被排除在外,并且分析时间也大大减少。通过使用特殊构造的采样列进行分析,然后将捕获的VMS捕获并通过GC技术直接进行分析。发现仪器分析规程在R〜2值为0.996的情况下可在0.1-55.13(μgg〜(-1))范围内产生线性校准,在R范围为0.1至65.17μgg〜(-1)) GC-FID和GC-MS方法的〜2值> 0.99。在所有分析的样品中,污水中的线性和循环VMS的量分别超过4.6 mg Nm〜(-3)和19.9 mg Nm〜(-3),而且,对VMS的溶剂吸收效率进行了估算,并获得了最高的吸收效率当使用丙酮作为主要溶剂时,得到的产物。高线性范围(0.1-65.17μg/ g)和低检测限(0.01μg/ g),定量限(0.04μg/ g)清楚地表明,该分析可以在其他独立的实验室中成功进行。所提出的方法为在线系统中的VMS分析创造了真实的前景。

著录项

  • 来源
  • 作者单位

    Faculty of Chemistry, Department Chemical Proecological Processes, Nicolaus Copernicus University, Gagarina 7 Street, 87-100 Torun, Poland,G.P.Chem., Stawki 75/63 Street, 27-400 Ostrowiec Swietokrzyski, Poland;

    Faculty of Chemistry, Department Chemical Proecological Processes, Nicolaus Copernicus University, Gagarina 7 Street, 87-100 Torun, Poland;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    GC-MS; GC-FID; siloxanes; biogas; waste water treatment; absorption method;