A selective, simple and fast dispersive micro solid phase extraction method using magnetic graphene oxide (GO) as an efficient sorbent has been developed for the extraction, separation and speciation analysis of chromium ions. The method is based on different adsorption behaviour of Cr(VI) and Cr(III) species onto magnetic GO in aqueous solutions which allowed the selective separation and extraction of Cr(VI) in the pH range of 2.0-3.0. The retained Cr(VI) ions by the sorbent were eluted using 0.5mL of 0.5molL(-1) nitric acid solution in methanol and determined by FLame atomic absorption spectrometry. Total chromium content was determined after the oxidation of Cr(III) to Cr(VI) by potassium permanganate. All effective parameters on the performance of the extraction process were thoroughly investigated and optimised. Under the optimised conditions, the method exhibited a linear dynamic range of 0.5-50.0 mu gL(-1) with a detection limit of 0.1 mu gL(-1) and pre-concentration factor of 200. The relative standard deviations of 3.8% and 4.6% (n=8) were obtained at 25.0 mu gL(-1) level of Cr(VI) for intra- and inter-day analysis, respectively. The method was successfully applied to the speciation and determination of Cr(VI) and Cr(III) in environmental water samples.
机译:已经开发出一种选择性,简单和快速分散的微固相萃取方法,该方法以氧化石墨烯(GO)为有效吸附剂,用于铬离子的萃取,分离和形态分析。该方法基于水溶液中磁性GO上Cr(VI)和Cr(III)物种在磁性GO上的不同吸附行为,从而可以在pH范围为2.0-3.0的条件下选择性分离和萃取Cr(VI)。用0.5mL的0.5molL(-1)硝酸的甲醇溶液洗脱吸附剂保留的Cr(VI)离子,并通过火焰原子吸收光谱法测定。高锰酸钾将Cr(III)氧化为Cr(VI)后,测定总铬含量。对萃取过程性能的所有有效参数都进行了彻底研究和优化。在优化的条件下,该方法的线性动态范围为0.5-50.0 mu gL(-1),检测极限为0.1 mu gL(-1),预浓系数为200。相对标准偏差为3.8%,在25.0μgL(-1)的Cr(VI)水平下分别获得4.6%(n = 8)进行日内和日间分析。该方法已成功应用于环境水样中六价铬和三价铬的形态和测定。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号