This paper describes high voltage impulse measurements made under controlled conditions in two national measurement institutes to establish the best agreement that could be achieved in comparison measurements on small reference resistor dividers. These measurements at NML and INMS show that the peak voltage of a smooth impulse (measured as the peak reading of the record times the scale factor) can be measured in each laboratory with relative agreement within 4 mV/V. The uncertainty of this relative agreement, calculated from the standard deviation of the differences in each set of measurements, is 2 mV/V at a level of confidence of 95%. The relative agreement of front times was within 15 ms/s, with an uncertainty of 4 ms/s. The relative agreement of times to half-value was within 4 ms/s with an uncertainty of 2 ms/s.
机译:本文介绍了在两家国家测量机构在受控条件下进行的高压脉冲测量,以建立在小型参考电阻分压器的比较测量中可以达到的最佳协议。在NML和INMS上进行的这些测量表明,可以在每个实验室中以4 mV / V的相对一致性来测量平滑脉冲的峰值电压(测量为记录的峰值读数乘以比例因子)。根据每组测量值的差异的标准偏差计算出的此相对一致性的不确定度为2 mV / V,置信度为95%。前置时间的相对一致性在15 ms / s以内,不确定度为4 ms / s。时间与半值的相对一致性在4 ms / s以内,不确定度为2 ms / s。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号