The Bureau International des Poids et Mesures (BIPM) has established a measurement chain allowing calibration of capacitance standards in terms of the quantized Hall resistance (QHR). An important element in the chain is a quadrature bridge linking a pair of ac resistors of values 2R_(K)≈51.6 kΩ to a pair of capacitance standards. The quadrature bridge can be operated at five different frequencies: 513, 1027, 1541, 3082, and 6164 Hz. For such measurements, we use different ratios (1/1, 4/1 and 1/4) for the main inductive voltage divider in the quadrature bridge and three different pairs of capacitors of values 3000, 2000, and 1000 pF. A calculable coaxial resistance of 1290.6 Ω (R_(K)/20) is used as a reference to evaluate the frequency dependence of the 51.6-kΩ resistances. This allows the calibration of capacitance standards at the five different frequencies. The measured frequency dependences of 10 and 100 pF capacitance standards are reported.
机译:国际植物保护组织(BIPM)建立了一条测量链,可以根据量化的霍尔电阻(QHR)校准电容标准。链中的一个重要元素是一个正交桥,将一对值2R_(K)≈51.6kΩ的交流电阻器与一对电容标准相连。正交电桥可以在五个不同的频率上运行:513、1027、1541、3082和6164 Hz。对于此类测量,我们对正交电桥中的主电感分压器和值3000、2000和1000 pF的三对不同的电容器使用不同的比率(1 / 1、4 / 1和1/4)。 1290.6Ω(R_(K)/ 20)的可计算同轴电阻用作评估51.6-kΩ电阻的频率依赖性的参考。这样可以在五个不同的频率下校准电容标准。报告了10和100 pF电容标准品的频率依赖性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号