An improved method for calibrating an open-ended coaxial sensor is proposed. The calibration utilizes the measurements of an open, a short, and a short-cavity. These terminations are inexpensive to make and result in a calibration that depends only on the geometry of the sensor. The short-cavity is modeled by waveguide modal techniques and the theoretical reflection coefficient determined to any accuracy. Consequently, an improvement in the accuracy of the measurements is obtained over a large bandwidth. The calibration was tested by comparing theoretical and experimental values of the complex permittivity for common liquids, and the discrepancy was seen to be small.
机译:提出了一种校准开放式同轴传感器的改进方法。校准利用开路,短路和短腔的测量值。这些终端的制造成本低廉,其校准仅取决于传感器的几何形状。短腔通过波导模态技术建模,理论反射系数确定为任意精度。因此,在大带宽上获得了测量精度的提高。通过比较普通液体的复介电常数的理论值和实验值来测试校准,发现差异很小。