首页> 外文期刊>IEEE Transactions on Instrumentation and Measurement >Feedback control method for estimating the oxygen uptake rate in activated sludge systems
【24h】

Feedback control method for estimating the oxygen uptake rate in activated sludge systems

机译:估算活性污泥系统中氧气吸收率的反馈控制方法

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

The measurement and utilization of the respiration rate or oxygen uptake rate (OUR) is very important in activated sludge system control. It provides information about the quality of the influent, activated sludge quality and can indicate the presence of toxic elements that can poison the system. The existing methods for continuously measuring and estimating the OUR have, generally, a long sampling interval of a few minutes. An alternative respiration rate meter with much shorter response time is proposed. The results of simulation studies, as well as experimental results of a microcontroller based data acquisition system connected to a PC, around a laboratory scale biological reactor are presented.
机译:呼吸速率或氧气吸收率(OUR)的测量和利用在活性污泥系统控制中非常重要。它提供有关进水质量,活性污泥质量的信息,并可以指示可能会毒害系统的有毒元素。连续测量和估算OUR的现有方法通常具有几分钟的长采样间隔。提出了一种响应时间短得多的替代呼吸速率仪。介绍了模拟研究的结果,以及在实验室规模的生物反应器周围连接到PC的基于微控制器的数据采集系统的实验结果。