A quadrature bridge which will be used in the chain of measurements from the QHR to the standard of capacitance at ETL has been developed. The bridge may be balanced at several frequencies including the conventional 10/2/spl pi/ kHz (i.e., /spl omega/=10/sup 4/ rad/s). At its present stage of development the bridge achieves a relative standard uncertainty of 2/spl times/10/sup -7/ in comparing 1 nF capacitors and 100 k/spl Omega/ resistors at frequencies from 3/8/spl times/10/2/spl pi/ kHz to 10/2/spl pi/ kHz. With further development it is expected that a relative standard uncertainty of about 5/spl times/10/sup -8/ will be achieved.
展开▼
机译:已经开发出将在从QHR到ETL的电容标准的测量链中使用的正交桥。可以在包括传统的10/2 / spl pi / kHz(即/ splω/ = 10 / sup 4 / rad / s)的几个频率上平衡电桥。在目前的发展阶段,通过比较1 nF电容器和100 k / spl Omega /电阻器(频率为3/8 / spl次/ 10 /),该电桥的相对标准不确定度为2 / spl次/ 10 / sup -7 /。 2 / spl pi / kHz至10/2 / spl pi / kHz。随着进一步的发展,预期将实现约5 / spl乘以/ 10sup -8 /的相对标准不确定度。