首页> 外文期刊>Industrial Electronics, IEEE Transactions on >Start-Up Process and Step Response of a DC–DC Converter Loaded by Constant Power Loads
【24h】

Start-Up Process and Step Response of a DC–DC Converter Loaded by Constant Power Loads

机译:恒定功率负载下的DC-DC转换器的启动过程和阶跃响应

获取原文
获取原文并翻译 | 示例
       

摘要

Constant power loads (CPLs) are very common in multiconverter power system applications. Buck converters loaded by CPLs have different start-up and step-response processes from the resistive load. This paper analyzes the start-up process and step response of an average current-controlled buck converter with CPLs based on the phase portrait method. Design criteria rules have been proposed to achieve system stability during start-up and load transient processes. The proper current-limiting value is proposed accordingly to avoid the instability during the start-up and load change dynamics. Simulation and experimental results verify the analysis and the proposed proper current-limit value.
机译:恒定功率负载(CPL)在多转换器电源系统应用中非常普遍。 CPL加载的降压转换器与阻性负载具有不同的启动和阶跃响应过程。本文基于相画像法,分析了具有CPL的平均电流控制型降压转换器的启动过程和阶跃响应。已经提出了设计标准规则,以在启动和负载瞬态过程中实现系统稳定性。相应地提出了适当的限流值,以避免启动和负载变化动态过程中的不稳定。仿真和实验结果验证了分析结果和建议的适当电流限制值。