This paper presents a detailed analysis of circuit operation under ZVS and NON-ZVS conditions in a full-bridge high-frequency phase-shift control series resonant MOSFET inverter with the load of induction heating. Various modes of circuit operation both under ZVS and NON-ZVS conditions are first analyzed in details. The voltage and current equations of these circuits are then obtained and used for calculation of the waveforms by MATLAB program. The calculated results can lead to the consideration of various circuit parameters that determine ZVS or NON-ZVS operating conditions. The theoretical results are also verified by experimental ones, using a prototype test set rated at 3 kW.
机译:本文详细分析了感应加热负载下全桥高频相移控制串联谐振MOSFET逆变器在ZVS和NON-ZVS条件下的电路工作情况。首先详细分析ZVS和NON-ZVS条件下的各种电路工作模式。然后获得这些电路的电压和电流方程,并通过MATLAB程序将其用于波形计算。计算结果可能导致需要考虑确定ZVS或NON-ZVS工作条件的各种电路参数。使用额定功率为3 kW的原型测试仪,实验结果也验证了理论结果。