A dc-link voltage measurement method is proposed in this letter. The proposed method is suitable for a power converter with μ-processor control. The dc-link voltage is directly measured so that the measurement error caused by the resistive voltage divider can be removed. The circuit is designed as simply as possible to avoid errors caused by inaccuracies in the components. DC-link voltage sampling and A/D conversion are synchronized with the timing of the PWM modulator to avoid instances where power-converter switching generates strong electromagnetic noise. The validity of the proposed method is verified through an experiment.
机译:本文提出了一种直流母线电压测量方法。所提出的方法适用于具有μ处理器控制的功率转换器。直接测量直流链路电压,以便消除由电阻分压器引起的测量误差。电路设计得尽可能简单,以避免由于组件不正确而引起的错误。直流母线电压采样和A / D转换与PWM调制器的时序同步,以避免电源转换器切换产生强烈电磁噪声的情况。通过实验验证了该方法的有效性。