首页> 外文期刊>IEEE Transactions on Nuclear Science >Development of a Low- Cavity-Type Beam Position Monitoring System
【24h】

Development of a Low- Cavity-Type Beam Position Monitoring System

机译:低腔型光束位置监控系统的开发

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

A beam position monitor (BPM) with the nanometer-scale position resolution and the decay time of approximately 20 ns is developed as an interaction point BPM, to verify the nanometer stabilization of the International Linear Collider beam trains at the Accelerator Test Facility (ATF), High Energy Accelerator Research Organization (KEK). The developed low- cavity BPM consists of a one-cell sensor cavity and a one-cell reference cavity. An electronic system is developed, based on the beam test results, to process the signals from the BPM. The beam position resolution of the low- cavity BPM with the electronics system is measured at the ATF2 beam line of KEK, and the results of the beam tests conducted on the developed low- cavity-type BPM are described.
机译:开发了具有纳米级位置分辨率和约20 ns衰减时间的光束位置监视器(BPM)作为相互作用点BPM,以验证国际直线对撞机光束列在加速器测试设施(ATF)的纳米稳定性。 ,高能加速器研究组织(KEK)。开发的低腔BPM由一个单元的传感器腔和一个单元的参考腔组成。基于光束测试结果,开发了一个电子系统来处理来自BPM的信号。在KEK的ATF2光束线上测量了带电子系统的低腔BPM的光束位置分辨率,并描述了在已开发的低腔型BPM上进行的光束测试的结果。