We examine the accuracy of the air-filled stripline cavity in measuring the dielectric and magnetic properties of bulk materials in the frequency range of 150-2000 MHz. Measured data on complex permittivity and permeability for several different-sized specimens of dielectric and magnetic materials were compared with reference values obtained using other techniques of known uncertainties. Major differences were noted for both complex permittivity and permeability data, and we largely attribute these to less-than-optimal perturbation of the internal cavity fields by the material specimens under test. The technique is particularly unsuited to measuring the dielectric loss of the higher-permittivity low-loss materials due to energy scatter by the specimen under test. In order to improve measurement accuracy, we suggest guidelines on the range of specimen electric and magnetic volume needed for optimal cavity perturbation.
机译:我们在150-2000 MHz频率范围内检查了充气带状线腔在测量散装材料的介电和磁性能方面的准确性。将几种不同尺寸的介电和磁性材料的复介电常数和磁导率的测量数据与使用其他已知不确定性技术获得的参考值进行了比较。注意到复数介电常数和磁导率数据都存在主要差异,我们将其主要归因于被测材料样本对内腔场的干扰小于最佳。该技术特别不适用于测量由于被测样品的能量散射而导致的高介电常数低损耗材料的介电损耗。为了提高测量精度,我们建议了有关最佳空腔扰动所需的样品电和磁体积范围的准则。