An improved dynamic range instantaneous frequency measurement system based on four-wave mixing effect in a highly nonlinear fiber was practically demonstrated. A closed-form model was developed to predict the behavior of the system. The model predicted that the system output would have a low frequency voltage which was a function of RF input frequency. The system performance was also practically demonstrated. The system characterization showed a 0.04–40-GHz frequency measurement range with 51-dB dynamic range for 100-MHz measurement error at the end of the band. A maximum relative measurement error of 0.35% was achieved over the entire frequency range. This dynamic range was achieved by employing the lock-in amplification technique.
机译:实际演示了一种在高度非线性光纤中基于四波混频效应的改进的动态范围瞬时频率测量系统。开发了一种封闭形式的模型来预测系统的行为。该模型预测系统输出将具有一个低频电压,该电压是RF输入频率的函数。系统性能也得到了实际证明。系统特性表明,在频段末尾,对于100 MHz的测量误差,具有0.04–40 GHz的频率测量范围和51 dB的动态范围。在整个频率范围内,最大相对测量误差为0.35%。该动态范围是通过采用锁定放大技术实现的。