首页> 外文期刊>IEEE Transactions on Magnetics >Simulation analysis of three- phase current type AC-to-DC converter with high power factor
【24h】

Simulation analysis of three- phase current type AC-to-DC converter with high power factor

机译:高功率因数三相电流型交直流变换器的仿真分析

获取原文
获取原文并翻译 | 示例
           

摘要

A new three-phase current type AC-to-DC power converter has been developed by the authors. This paper describes the principle of the circuit operation and the circuit configuration of the AC-to-DC power converter controlled by PWM. Simulation analyses of each waveform, such as AC and DC voltages and currents, are calculated by Euler's method. The simulated values of the total power factor agreed with the measured values within the difference of 5.8% on the condition of full load, 10 kW. When the AC side voltage is unbalanced, it is found by simulation that the total harmonic distortion controlled by both feedforward control and AC side current feedback control (proportion gain, k/sub 4/=1) is restrained at only 38% compared with only feedforward control (k/sub 4/=0).
机译:作者已经开发了一种新型的三相电流型AC-DC电源转换器。本文描述了由PWM控制的AC-DC电源转换器的电路工作原理和电路配置。每个波形的仿真分析,例如交流和直流电压和电流,都是通过Euler方法计算得出的。在满载10 kW的条件下,总功率因数的模拟值与测量值相符,相差5.8%。通过仿真发现,当交流侧电压不平衡时,由前馈控制和交流侧电流反馈控制所控制的总谐波失真(比例增益,k / sub 4 / = 1)仅被限制在38%。前馈控制(k / sub 4 / = 0)。