首页> 外文期刊>IEEE Sensors Letters >A Novel Background Calibration Technique for Microwave Radiometric Sensors in Indoor Applications
【24h】

A Novel Background Calibration Technique for Microwave Radiometric Sensors in Indoor Applications

机译:室内应用中微波辐射传感器的新型背景校准技术

获取原文
获取原文并翻译 | 示例
       

摘要

This letter presents a novel background calibration technique for microwave radiometers in indoor applications such as security sensing for static targets where unknown noise sources may add to background noise and degrade measurement accuracy. Such a background correction is important for absolute measurement of radiometric apparent temperature as opposed to relative measurement of contrast. The technique is validated by measuring the error in apparent temperature of hot water using a 23.55 GHz radiometer in an uncontrolled environment where the background noise is artificially increased using a diode-based noise source. The calibration technique reduced the prediction error introduced due to incorrect assumptions about the background by approximately 1 to 3 K.
机译:这封信提出了一种新的室内应用中微波辐射仪的新型背景校准技术,例如静态目标的安全感,其中未知的噪声源可能会增加背景噪声和降低测量精度。这种背景校正对于绝对测量辐射表观温度的绝对测量是重要的,而不是相对测量对比度。通过在使用基于二极管的噪声源的不受控制的环境中使用23.55GHz辐射计测量热水的表观温度的误差来验证该技术。校准技术通过大约1到3 K的错误假设而引入的预测误差减少了预测误差。