首页> 外文期刊>IEEE Microwave and Guided Wave Letters >Comments on 'Numerical errors in the computation of impedances by FDTD method and ways to eliminate them' [with reply]
【24h】

Comments on 'Numerical errors in the computation of impedances by FDTD method and ways to eliminate them' [with reply]

机译:关于“通过FDTD方法计算阻抗中的数值误差及其消除方法”的评论[和回复]

获取原文
获取原文并翻译 | 示例
           

摘要

For original paper, see Fang and Xue, ibid., vol. 5, no. 1, pp. 6-8 (Jan. 1995). The original paper presents a new formula for the calculation of the characteristic impedance of transmission lines, Z/sub 0/, using the FDTD method. This formula eliminates the numerical errors due to the offset of voltages and currents in space and time. The commenters recalculate the two examples given and confirm the presented results. However, they point out that using the exact formula for the characteristic impedance yields a value of Z/sub 0/ = 50.2 /spl Omega/ for the stripline investigated. In response to the comments, the original authors analyze the variation of the numerical error with respect to the space step.
机译:有关原始论文,请参见Fang和Xue,同上,第一卷。 5号1,第6-8页(1995年1月)。原始论文提出了一种使用FDTD方法计算传输线特性阻抗Z / sub 0 /的新公式。该公式消除了由于电压和电流在时空上的偏移而引起的数值误差。评论者重新计算给出的两个示例,并确认给出的结果。但是,他们指出,对于所研究的带状线,使用特性阻抗的精确公式可得出Z / sub 0 / = 50.2 / spl Omega /的值。为了回应这些评论,原始作者分析了数值误差相对于空间步长的变化。