Distributed temperature sensing (DTS) systems have been installed by power utilities on underground cables to monitor in real time the cable surface temperature for reliable and cost-effective operation of cables. However, full use of advanced DTS depends on the solution of two problems. One is to determine the conductor temperature from the measured surface temperature, and the other is to predict the maximum allowable carrying currents under emergency overloading conditions. A technique for solving these two problems is developed, the basic principle of which is based on estimation of the soil thermal parameters by matching the computed thermal field to that obtained from measurements. The technique developed makes use of two basic methods -- the finite-element method and a gradient-based optimisation method. Laboratory tests were carried out to verify this technique.
机译:电力公司已在地下电缆上安装了分布式温度感测(DTS)系统,以实时监视电缆表面温度,从而可靠且经济高效地运行电缆。但是,充分使用高级DTS取决于解决两个问题。一种是根据测得的表面温度确定导体温度,另一种是预测紧急过载条件下的最大允许载流。开发了解决这两个问题的技术,其基本原理是通过将计算出的热场与测量值相匹配来估算土壤热参数。开发的技术利用了两种基本方法-有限元方法和基于梯度的优化方法。进行了实验室测试以验证该技术。