首页> 外文期刊>Hydro review >Mitigating Operational Effects of AAR at Otto Holden
【24h】

Mitigating Operational Effects of AAR at Otto Holden

机译:缓解奥托霍顿AAR的作战影响

获取原文
获取原文并翻译 | 示例
       

摘要

The effects of concrete movement and growth, a result of alkali aggregate reaction (AAR), have been observed since the early 1970s at the 240-MW Otto Holden Generating Station. Major overhauls were conducted on all eight units from 1980 to 1988, and the effects of concrete movement were noticed during turbine and generator component alignments. Otto Holden Generating Station - located on the Ottawa River, near Mattawa, Ontario, Canada - has been operating since 1952.The powerhouse has eight generating units with a total capacity of 240 MW under a gross head of 77 feet. All eight units have the same Westinghouse generators. Units G1 to G4 are Allis Chalmers turbines and G5 to G8 are John Inglis turbines. It is owned and operated by Ontario Power Generation Inc. (OPG).
机译:自1970年代初以来,在240兆瓦奥托霍顿发电站就已经观察到混凝土运动和生长的影响,这是碱骨料反应(AAR)的结果。从1980年到1988年,对所有8个机组进行了大修,并且在涡轮机和发电机组件对准期间注意到了混凝土运动的影响。 Otto Holden发电站位于加拿大安大略省马塔瓦附近的渥太华河上,自1952年开始运营,该发电站拥有八台发电机组,总容量为240兆瓦,总水头高度为77英尺。所有八个单元都具有相同的西屋发电机。 G1至G4机组为Allis Chalmers涡轮机,G5至G8机组为John Inglis涡轮机。它由安大略发电公司(OPG)拥有和运营。