Different methods for estimation of the surface coverage by extractives and lignin were critically compared. For data collection, four state-of-the-art X-ray photoelectron spectroscopy (XPS) instruments located in four different laboratories were used. Hand sheets of one mechanical and two chemical pulp samples were prepared in one laboratory and distributed among the other participants. The XPS results based on O/C ratios and curve fitting of the C 1s peak had very good intra- and interlaboratory variation for extracted and non-extracted pulp samples. The estimations of surface coverage by extractives and lignin also had acceptable intra- and interlaboratory variation. However, significant differences were observed between the results for the various methods. Estimation of surface coverage by extractives based on O/C ratios was much higher than that based on the C1 component analysis in the case of mechanical and unbleached chemical pulp. The surface coverage by lignin of mechanical pulp was reproducibly detected based on O/C ratios, C1 component analysis and by labelling with mercury acetate. The same data were, however, rather scattered if they were collected with these three methods for bleached and unbleached chemical pulp. In spite of the differences, similar trends regarding the pulp type could be observed. We interpret the results as indicating that the surface coverage for both extractives and lignin should not be considered as absolute "true" values, but rather as relative values, which are reliable only for comparison of samples for the same instrument. Even for relative comparisons, we recommend the selection of a strict experimental set-up for spectral acquisition and data treatment when applying any of the instruments and calculation models currently available.
机译:严格比较了通过萃取剂和木质素估算表面覆盖率的不同方法。为了收集数据,使用了位于四个不同实验室的四台最先进的X射线光电子能谱(XPS)仪器。在一个实验室中准备了一份机械纸浆样本和两份化学纸浆样本的手抄纸,并分发给其他参与者。基于O / C比和C 1s峰的曲线拟合的XPS结果对于提取和未提取的纸浆样品在实验室内和实验室间的变化非常好。提取物和木质素对表面覆盖率的估计也具有可接受的实验室内和实验室间变化。但是,在各种方法的结果之间观察到显着差异。在机械和未漂白化学纸浆的情况下,基于O / C比的萃取物对表面覆盖率的估计要比基于C1成分分析的萃取率高得多。根据O / C比,C1成分分析和用乙酸汞标记,可重复检测机械浆木质素的表面覆盖率。但是,如果使用这三种方法对漂白和未漂白的化学纸浆进行收集,则相同的数据相当分散。尽管存在差异,但可以观察到关于纸浆类型的相似趋势。我们将结果解释为表明,提取物和木质素的表面覆盖率均不应视为绝对“真实”值,而应视为相对值,这仅对于比较同一仪器的样品而言是可靠的。即使是进行相对比较,我们也建议在使用当前可用的任何仪器和计算模型时,为光谱采集和数据处理选择严格的实验设置。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号