首页> 外文期刊>Heat and mass transfer >Critical heat flux in forced convective boiling with a plane jet (Revised correlation for saturated condition)
【24h】

Critical heat flux in forced convective boiling with a plane jet (Revised correlation for saturated condition)

机译:平面射流强制对流沸腾中的临界热通量(饱和条件的修正相关性)

获取原文
获取原文并翻译 | 示例

摘要

Critical heat flux (CHF) has been measured in saturated forced convective boiling with a wall jet on a rectangular heated surface of 40 and 80 mm in length and 20 mm in width. The jet velocity is varied from 3 to 15 m/s, and the system pressure is 0.1, 0.2, and 0.4 Mpa for R13. It is found that the existing correlation for satura- tion condition can be applied to the CHF at high and low ρ_1/ρ_g values (e.g. water and R22), but hardly to the CHF at medium ρ_1/ρ_g values (e.g.R113 at 0.2 and 0.4 Mpa). A revised correlation is proposed to predict most of the CHF data within an accuracy of ±25/100.
机译:临界热通量(CHF)是在壁面射流在长度为40和80毫米,宽度为20毫米的矩形加热表面上通过饱和强制对流沸腾测量的。喷射速度在3到15 m / s之间变化,R13的系统压力为0.1、0.2和0.4 Mpa。已经发现,饱和条件的现有相关性可以应用于高和低ρ_1/ρ_g值(例如,水和R22)的CHF,但是几乎不能应用于中度ρ_1/ρ_g值(例如,R113的0.2和0.2)。 0.4 Mpa)。提出了修订的相关性,以在±25/100的精度内预测大多数CHF数据。