首页> 外文期刊>Heart >Diagnostic accuracy of myocardial perfusion imaging and stress echocardiography for the diagnosis of left main and triple vessel coronary artery disease:a comparative meta-analysis
【24h】

Diagnostic accuracy of myocardial perfusion imaging and stress echocardiography for the diagnosis of left main and triple vessel coronary artery disease:a comparative meta-analysis

机译:心肌灌注显像和应力超声心动图对左主干和三支冠状动脉疾病的诊断准确性:比较荟萃分析

获取原文
获取原文并翻译 | 示例
       

摘要

Objectives Compare the diagnostic performance of stress echocardiography (SE) and myocardial perfusion imaging (MPI) for the diagnosis of left main disease (LM) and triple vessel disease (TVD). Background Limited comparative data on MPI and SE for the detection of LM and TVD (high-risk coronary artery disease) exist in the literature. Methods Quantitative meta-analysis was performed using studies identified by systematic electronic literature search. Articles were included if they reported data on exercise, dobutamine SE or exercise, adenosine, dipyridamole, thallium201, technetium 99m sestamibi MPI and used coronary angiography as the reference test. Summary receiver-operating characteristic (SROC) curves were constructed for each imaging modality. Additionally, pooled sensitivity, specificity and likelihood ratios were calculated per modality. Meta-regression was performed to adjust for patient and study characteristics.rnResults Thirty-two studies met inclusion criteria; 23 (MPI-15; SE-14; Common studies-6) provided sufficient data for analysis. In a SROC model comparing the two imaging modalities, SE was associated with higher area under curve (0.82 (0.03) vs 0.73 (0.02), p=0.01) and index Q* value (0.75 (0.02) vs 0.67 (0.02), p=0.01). Using pooled summary point estimates, SE had higher pooled sensitivity (94% vs 75%, p<0.001) and lower negative likelihood ratio (0.21 vs 0.47, p<0.001) compared to MPI. No evidence of a difference in the pooled specificity (40% vs 48%, p=0.16) and positive likelihood ratio (1.52 vs 1.58, p=0.36) was seen between the two stress modalities. Pooled diagnostic OR on meta-regression (9.78 vs 4.06, p=0.02) remained significantly higher for SE compared to MPI for identification of LM and TVD even after adjustment for study characteristics.rnConclusions Since LM alone or in combination with TVD are categorised as representing potentially life-threatening variants of CAD, a screening test with high sensitivity, low negative likelihood ratio or higher discriminatory capacity would be desirable for risk stratification. In the absence of a direct head-to-head comparison of the diagnostic accuracies of SE and MPI, our findings indicate that SE appears to be the preferred screening modality for high-risk coronary artery disease.
机译:目的比较压力超声心动图(SE)和心肌灌注成像(MPI)在诊断左主干疾病(LM)和三支血管疾病(TVD)中的诊断性能。背景技术文献中存在用于检测LM和TVD(高危冠状动脉疾病)的MPI和SE有限的比较数据。方法采用系统电子文献检索确定的研究进行定量荟萃分析。如果他们报告了运动,多巴酚丁胺SE或运动,腺苷,双嘧达莫、, 201,tech 99m司他他比MPI的数据,并使用冠状动脉造影作为参考测试,则包括这些文章。为每种成像方式构建了摘要接收器工作特性(SROC)曲线。另外,针对每种方式计算合并的敏感性,特异性和可能性比。进行Meta回归以适应患者和研究特征。rn结果32项研究符合纳入标准; 23(MPI-15; SE-14; Common Studies-6)提供了足够的数据进行分析。在比较这两种成像方式的SROC模型中,SE与曲线下面积较高相关(0.82(0.03)对0.73(0.02),p = 0.01)和指标Q *值(0.75(0.02)对0.67(0.02),p = 0.01)。使用汇总汇总点估计,与MPI相比,SE具有更高的汇总敏感性(94%vs 75%,p <0.001)和更低的负似然比(0.21 vs 0.47,p <0.001)。两种应激方式之间没有发现合并特异性(40%vs 48%,p = 0.16)和阳性似然比(1.52 vs 1.58,p = 0.36)差异的证据。即使对研究特征进行了调整后,SE的荟萃诊断OR(9.78 vs 4.06,p = 0.02)仍比MPI显着高于MPI来鉴定LM和TVD。rn结论由于LM单独或与TVD结合被归类为代表对于潜在的危及生命的CAD变体,高灵敏度,低负似然比或较高区分能力的筛查测试,对于风险分层来说是理想的。在没有直接比较SE和MPI的诊断准确性的情况下,我们的发现表明SE似乎是高危冠状动脉疾病的首选筛查方式。

著录项

  • 来源
    《Heart》 |2010年第12期|p.956-966|共11页
  • 作者单位

    Department of Internal Medicine, Detroit Medical Center, Wayne State University,Detroit, Michigan, USA;

    rnDepartment of Internal Medicine, Detroit Medical Center, Wayne State University,Detroit, Michigan, USA;

    rnDepartment of Internal Medicine, Detroit Medical Center, Wayne State University,Detroit, Michigan, USA;

    rnDivision of Cardiology, Detroit Medical Center, Wayne State University, Detroit, Michigan,USA;

    rnDepartment of Biostatistics,Detroit Medical Center, Wayne State University, Detroit,Michigan, USA;

    rnDepartment of Biostatistics,Detroit Medical Center, Wayne State University, Detroit,Michigan, USA;

    rnDivision of Cardiology, Detroit Medical Center, Wayne State University, Detroit, Michigan,USA;

    rnInternal Medicine Division of Cardiology, Wayne State University, Harper University Hospital, 8 Brush,3990 John R, Detroit, Michigan 48201, USA;

  • 收录信息 美国《科学引文索引》(SCI);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号