首页> 外文期刊>Geotechnique >Applicability and accuracy of the initially dry and initially wet contact filter paper tests for matric suction measurement of geosynthetic clay liners
【24h】

Applicability and accuracy of the initially dry and initially wet contact filter paper tests for matric suction measurement of geosynthetic clay liners

机译:初干和初湿接触滤纸测试在土工合成粘土衬里的基质吸力测量中的适用性和准确性

获取原文
获取原文并翻译 | 示例
       

摘要

An initially wet contact filter paper test (IW-CFPT) and an initially dry contact filter paper test (ID-CFPT) were used to examine the wetting paths of geosynthetic clay liners, including non-contact filter paper tests for comparative purposes. The CFPTs were applied to both geosynthetic clay liner faces to examine the effect of geotextile type on capillary contact. The non-woven geotextile face was found to be more likely to cause capillary breaks than the woven geotextile face. Both IW- and ID-CFPTs were found to be applicable to geosynthetic clay liners within their accurate upper matric suction measurement limits of 146 kPa and 66 kPa, respectively.
机译:最初使用湿接触滤纸测试(IW-CFPT)和最初使用干接触滤纸测试(ID-CFPT)来检查土工合成粘土衬里的润湿路径,包括非接触滤纸测试,以作比较。将CFPT应用于两个土工合成材料的粘土衬里面,以检验土工布类型对毛细管接触的影响。发现非织造土工织物面比织造土工织物面更可能引起毛细破坏。发现IW-CFPT和ID-CFPT均适用于土工合成粘土衬里,其精确的基质吸力测量上限分别为146 kPa和66 kPa。

著录项

  • 来源
    《Geotechnique》 |2015年第9期|780-787|共8页
  • 作者单位

    Monash Univ, Melbourne, Vic 3004, Australia;

    Monash Univ, Melbourne, Vic 3004, Australia|Univ Surrey, Guildford GU2 5XH, Surrey, England;

    Monash Univ, Melbourne, Vic 3004, Australia;

    Monash Univ, Melbourne, Vic 3004, Australia;

    Queens Univ, Kingston, ON, Canada;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    geosynthetics; geotextiles; laboratory tests; suction; time dependence;

    机译:土工合成材料;土工织物;实验室测试;吸力;时间依赖性;
  • 入库时间 2022-08-18 00:12:00