The power and energy of the ASDEX Upgrade (AUG) tokamak are provided by two separate 10.5 kV, 110-85 Hz networks based on the flywheel generators EZ3-EZ4 in addition to the generator EZ2 dedicated to the toroidal field coil. The 10.5 kV networks supply the thyristor converters allowing fast control of the DC currents in the AUG poloidal field coils. Two methods for improving the load power factor in the present experimental campaign of AUG have been investigated, namely the control of the phase-to-neutral voltage in thyristor converters fitted with neutral thyristors, such as the new 145 MVA modular thyristor converter system (Group 6), and reactive power control achieved by means of static VAr compensators (SVC). The paper shows that reliable compensation up to 90 MVAr was regularly achieved and that electrical transients in SVC modules can be kept at an acceptable level. The paper will discuss the results from the reactive power reduction by SVC and neutral thyristor control and draw a comparative conclusion.
机译:ASDEX升级(AUG)托卡马克的功率和能量由两个单独的10.5 kV,110-85 Hz网络组成,这些网络基于飞轮发电机EZ3-EZ4以及专用于环形场线圈的发电机EZ2提供。 10.5 kV网络为晶闸管转换器供电,从而可以快速控制AUG极向场线圈中的直流电流。在AUG当前的实验活动中,研究了两种改善负载功率因数的方法,即控制装有中性晶闸管的晶闸管转换器的相-中性电压,例如新型145 MVA模块化晶闸管转换器系统(组6),以及通过静态VAr补偿器(SVC)实现的无功功率控制。本文表明,可以定期实现高达90 MVAr的可靠补偿,并且SVC模块中的电气瞬变可以保持在可接受的水平。本文将讨论通过SVC和中性晶闸管控制进行无功功率降低的结果,并得出比较结论。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号