首页> 外文期刊>Food Chemistry >Flame photometric determination of salinity in processed foods
【24h】

Flame photometric determination of salinity in processed foods

机译:火焰光度法测定加工食品中的盐度

获取原文
获取原文并翻译 | 示例
       

摘要

The sodium contents determined by flame photometry were used to estimate the salinities of processed foods. The interference effects of potassium and calcium ions on the determination of sodium ion were studied. The threshold interfering patterns of potassium ion and calcium ion for the determination of sodium ion were observed in the model systems. Both of the ions showed enhancement effects on the signals of sodium determination and the increased signal strength depended on the concentration of the ions added above a threshold level. While low level calcium ion hardly interferes with the measurement of sodium ion, the potassium ion exerts marked interfering effects. The salinities based on the chloride contents from Mohr's titration method were obtained for comparison purpose. The salinities of 48 processed food samples determined by the two methods were positively correlated with r~2 = 0.9995 and did not show significant difference in the paired t tests (P = 0.2504). Overall, the flame photometric determination of sodium ion provides a rapid, less tedious and more accurate alternative for the quantification of salinity in processed foods.
机译:通过火焰光度法测定的钠含量用于估计加工食品的盐度。研究了钾离子和钙离子对钠离子测定的干扰作用。在模型系统中观察到钾离子和钙离子的阈值干扰模式,用于测定钠离子。两种离子均显示出对钠测定信号的增强作用,并且增加的信号强度取决于阈值水平以上所添加离子的浓度。虽然低水平的钙离子几乎不会干扰钠离子的测量,但钾离子会发挥显着的干扰作用。为了进行比较,从莫尔滴定法获得了基于氯化物含量的盐度。两种方法测定的48个加工食品样品的盐度与r〜2 = 0.9995正相关,在配对t检验中无显着差异(P = 0.2504)。总体而言,火焰光度法测定钠离子为定量处理加工食品中的盐度提供了一种快速,简便而又准确的替代方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号