A series of compartment fire tests with multiple exposed timber surfaces have been undertaken to explore the effect of exposed timber on the fire dynamics and the potential for auto-extinction. A test with exposed wall and ceiling achieved auto-extinction after approximately 21 min. Firepoint theory is applied using temperature data at the charline, is shown to predict a mass loss rate dropping below the critical value at 20-21 min, and thus is successful in predicting auto-extinction. Additional uncertainties caused by delamination are explored, and recommendations for the use of auto-extinction in design are given.
机译:已经进行了一系列具有多个裸露木材表面的舱室防火测试,以探索裸露木材对火灾动力学的影响以及自动熄灭的可能性。墙壁和天花板裸露的测试在大约21分钟后自动熄灭。火点理论是通过使用Charline上的温度数据来应用的,它可以预测质量损失率在20-21分钟时降至临界值以下,因此成功地预测了自动熄灭。探索了由分层引起的其他不确定性,并提出了在设计中使用自动消光的建议。