Our aim was to investigate the diagnostic value of unenhanced MDCT in anemic patients. Fifty consecutive patients with proven anemia and 50 nonanemic matched group for age, sex and body mass index were evaluated. In either group, hemoglobin levels were assessed no more than 24 h from an unenhanced CT of the thorax. For each patient, the presence of a hyperattenuating aortic wall (aortic ring sign) and/or dense interventricular septum (subjective parameters) were identified by two radiologists who were blinded to the laboratory findings. Furthermore, the aortic CT attenuation values (objective parameter) were also obtained and correlated with the hemoglobin levels. The sensitivity and specificity in detecting anemia were calculated for each variable, and ROC analysis was generated for subjective and objective parameters. Subjective image analysis revealed that the aortic ring sign was more sensitive than the interventricular septum sign for anemia detection (84% vs. 72%), whereas this latter sign was more specific (100% vs. 92%). A good correlation (r = 0.60) was observed between the aortic CT attenuation values and the hemoglobin levels in the whole study population. Using a threshold of ≤35 HU for anemia diagnosis, the sensitivity and specificity of aortic CT attenuation value were 84% and 94%, respectively, with the largest area under the curve (0.89) among all diagnostic criteria. However, the best trade-off between sensitivity (80%) and specificity (100%) was obtained from combining both subjective and objective analysis. Interpreting anemia upon unnenhanced MDCT of the thorax is quite feasible. A diagnostic approach that considers both subjective and objective analysis offers the best trade-off between sensitivity and specificity.
机译:我们的目的是研究未增强的MDCT对贫血患者的诊断价值。评估了连续50例贫血患者和50个非贫血配对组的年龄,性别和体重指数。在任一组中,未经增强的胸部CT评估血红蛋白水平均不超过24小时。对于每位患者,两名放射科医生对实验室发现不知情,确定是否存在高衰减主动脉壁(主动脉环征)和/或致密的室间隔(主观参数)。此外,还获得了主动脉CT衰减值(客观参数)并将其与血红蛋白水平相关。计算每个变量检测贫血的敏感性和特异性,并针对主观和客观参数生成ROC分析。主观图像分析显示,对于贫血检测,主动脉环征比室间隔征更敏感(84%对72%),而后者的征象更特异性(100%对92%)。在整个研究人群中,主动脉CT衰减值与血红蛋白水平之间存在良好的相关性(r = 0.60)。使用≤35 HU的贫血诊断阈值,主动脉CT衰减值的敏感性和特异性分别为84%和94%,在所有诊断标准中曲线下面积最大(0.89)。然而,通过将主观和客观分析相结合,可以在敏感性(80%)和特异性(100%)之间取得最佳平衡。用未经增强的胸部MDCT解释贫血是很可行的。同时考虑主观和客观分析的诊断方法可在敏感性和特异性之间取得最佳平衡。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号