首页> 外文期刊>European Radiology >Mean diffusivity, fractional anisotropy maps, and three-dimensional white-matter tractography by diffusion tensor imaging. Comparison between single-shot fast spin-echo and single-shot echo-planar sequences at 1.5 Tesla
【24h】

Mean diffusivity, fractional anisotropy maps, and three-dimensional white-matter tractography by diffusion tensor imaging. Comparison between single-shot fast spin-echo and single-shot echo-planar sequences at 1.5 Tesla

机译:平均扩散率,分数各向异性图和通过扩散张量成像的三维白色物质束图。 1.5特斯拉下单次快速自旋回波和单次回波平面序列的比较

获取原文
获取原文并翻译 | 示例

摘要

Single-shot fast spin-echo (SSFSE)-based magnetic resonance imaging (MRI) has been introduced as a technique with less distortion and fewer artifacts for diffusion tensor imaging (DTI). The purpose of this study was to compare mean diffusivity maps, fractional anisotropy (FA) maps, and three-dimensional white-matter tractography using data obtained with SSFSE diffusion-tensor MRI technique and the much more common DTI method, echo-planar imaging (EPI), in the brain using a 1.5-Tesla clinical MR imager. Thirty patients with neurological disorders were scanned with both SSFSE-DTI and EPI-DTI using comparable scan times. Mean diffusivity and FA maps were calculated from the SSFSE-DTI and EPI-DTI data and qualitatively compared using two criteria. Three-dimensional fiber tracking was also performed on each data set. SSFSE-DTI produced image artifacts less frequently than EPI-DTI. However, demonstration of three-dimensional fiber-tracking of white matter on SSFSE-DTI was inferior to that on EPI-DTI. In conclusion, SSFSE-DTI is a promising alternative to conventional EPI-DTI imaging, producing fewer image artifacts and geometric distortions. However, for 3D streamline fiber-tracking, EPI data produced more consistent and reliable results.
机译:基于单次快速自旋回波(SSFSE)的磁共振成像(MRI)已被引入作为一种技术,该技术具有较少的失真和较少的伪影,可用于扩散张量成像(DTI)。这项研究的目的是使用SSFSE扩散张量MRI技术和更常见的DTI方法(回波平面成像)比较平均扩散率图,分数各向异性(FA)图和三维白色物质束图。使用1.5特斯拉(Tesla)临床MR成像器在大脑中进行测试。用可比较的扫描时间对30例神经系统疾病患者进行了SSFSE-DTI和EPI-DTI扫描。从SSFSE-DTI和EPI-DTI数据计算出平均扩散率和FA图,并使用两个标准进行定性比较。还对每个数据集执行了三维纤维跟踪。 SSFSE-DTI产生图像伪像的频率低于EPI-DTI。但是,在SSFSE-DTI上对白质进行三维纤维跟踪的演示效果不如EPI-DTI上的演示。总之,SSFSE-DTI是传统EPI-DTI成像的有前途的替代方法,产生的图像伪影和几何失真更少。但是,对于3D流线型光纤跟踪,EPI数据产生了更加一致和可靠的结果。

著录项

  • 来源
    《European Radiology》 |2008年第4期|830-834|共5页
  • 作者单位

    Department of Radiology Toho University 6-11-1 Omori-nishi Ota Tokyo 143-8541 Japan;

    Department of Radiology University of Yamanashi 1110 Shimokato Tamaho Nakakoma Yamanashi 409-3898 Japan;

    Department of Radiology Toho University 6-11-1 Omori-nishi Ota Tokyo 143-8541 Japan;

    Department of Radiology University of Yamanashi 1110 Shimokato Tamaho Nakakoma Yamanashi 409-3898 Japan;

    Department of Radiology University of Tokyo 7-3-1 Hongo Bunkyo Tokyo 113-8655 Japan;

    Department of Radiology University of Yamanashi 1110 Shimokato Tamaho Nakakoma Yamanashi 409-3898 Japan;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    SSFSE; EPI; Tensor; MRI; Tractography;

    机译:SSFSE;EPI;张量;MRI;运动成像;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号